A
Error Messages
McDATA OPENconnectors Command Line Interface USER MANUAL
A-2
Message
Error 09: Invalid Switch Description
Description
The value entered for the switch description is invalid.
Action
The description for the director or switch may contain 0–255
characters. Enter a description with 0–255 characters and re-submit. If
spaces are used, enclose the description in quotation marks.
Message
Error 10: Invalid Switch Location
Description
The value entered for the switch location is invalid.
Action
The location for the director or switch may contain 0–255 characters.
Enter a location with 0–255 characters and re-submit. If spaces are
used, enclose the location in quotation marks.
Message
Error 11: Invalid Switch Contact
Description
The value entered for the switch contact is invalid.
Action
The contact for the director or switch may contain 0–255 characters.
Enter a contact with 0–255 characters and re-submit. If spaces are
used, enclose the contact in quotation marks.
Message
Error 13: Invalid Port Number
Description
The value entered for the port number is invalid.
Action
Enter a port number within the range supported by your director or
switch. Valid values are:
0–15 for the Sphereon 3016 and Sphereon 3216
0–31 for the Sphereon 3032 and Sphereon 3232
0–31 for the ED-5000
0–63 for the Intrepid 6064
0–127 and 132–144 for the Intrepid 6140