Maxtronic Orion 410SR User Guide
61
Stor
age
Se
tu
p Settings
N-Sync Log
N-Sync log keeps records of all N-Sync jobs.
•
Date
: Displays the start date of the job.
•
Time
: Displays the start time of the job.
•
Profile
: Displays the profile name. If the log
entry is generated by the N-Sync Client, this
field will be replaced by ‘---’.
•
Local Share
: Displays the local share name
of the job.
•
Sync OP
: Displays the synchronization
operation of the job.
•
Remote Server
: Displays the remote server
name of the job.
•
Remote Share
: Displays the remote share name of the job.
•
Status of the N-Sync job
: Displays status of the job.
‘Done’ is displayed when the job has been completed successfully. A failed N-Sync job is
shown by a red error code. Refer to the following list for error code definitions:
– 1: Syntax or usage error.
– 2: Protocol incompatibility.
– 3: Errors selecting input/output, directories.
– 4: Requested action not supported: an attempt was made to manipulate a 64-bit file on a
platform that cannot support them or a request was made that is supported by the client
but not by the sever.
– 5: Error starting client-server protocol.
– 10: Error in socket I/O.
– 11: Error in file I/O.
– 12: Error in rsync protocol data stream.
– 13: Error with program diagnostics.
– 14: Error in IPC code.
– 20: Received SIGUSR1 or SIGINT.
– 21: Error returned by waitpid.
– 22: Error allocating core memory buffers.
– 23: Partial transfer due to error.
– 24: Partial transfer due to missing source files.
– 30: Timeout in data send/receive.
Summary of Contents for Orion 410SR
Page 1: ...Orion NAS 410SR User Manual 42 30000 5114 Version 1 2...
Page 2: ......
Page 3: ...MaxTronic Orion 410SR RAID Enabled NAS System User Manual...
Page 4: ......
Page 8: ...Maxtronic Orion 410SR User Guide...
Page 14: ......
Page 18: ...4 Maxtronic Orion 410SR User Guide Components of the Orion 410SR...
Page 28: ...14 Maxtronic Orion 410SR User Guide Using the Front Control Panel...
Page 38: ...24 Maxtronic Orion 410SR User Guide System Setup...