REMOVING LOCKING BRACKETS
FIG. 44-1
3.
Unbolt the locking brackets from
both cylinders
(FIG. 44-1)
.
To prevent damage to Liftgate, the locking bracket on each cylinder must be removed
before operating Liftgate.
CAUTION
LOCKING
BRACKET
CAP NUT
FLAT
WASHER
BOLT
LH CYLINDER
RH CYLINDER
LOCKING BRACKET
(2 PLACES)
STEP 10 - REMOVE LOCKING BRACKETS & CHECK
FOR INTERFERENCE - Continued