Pre-Installation Inspection:
Correct model
Correct capacity
Correct platform size
Correct options
Manuals & decals
Structural Inspection:
Inspect alignment of
fi
nal assembly
Inspect pump box secure mounting
Inspect all installation welds
Check roll pins, bolts and fasteners
Inspect tightness of hardware used to secure
liftgate to vehicle.
Ensure platform ramp tip touches ground or is
not more than
1/4”
off the ground.
Ensure bottom of underride tube is not more
than
21-1/2”
off the ground and not more than
11”
forward of the extreme rear of vehicle.
Hydraulic Inspection:
Proper
fl
uid level (See
CHECKING
HYDRAULIC FLUID
step in this manual.)
Check hydraulic
fi
ttings in pump box for leaks
Check hydraulic line connections for leaks
Electrical Inspection:
Check power/charge plug and terminal
Check for tight wire connections
Circuit breaker (150A) installed in battery box
(if equipped) or by truck/tractor battery.
Ensure batteries are fully charged, all cable
connections are tight & tiedowns are tight.
Inspect all solenoid connections
Check all wiring harness connections
Check electrical cable connections are tight &
secure.
Operation Inspection:
Check operation of all main and optional
control switches.
GPTLR-25 or GPTLR-33 only
Unloaded platform lowers in
6 sec
.
Unloaded platform raises in
15 sec
.
GPTLR-44 or GPTLR-55 only
Unloaded platform lowers in
10 sec
.
Unloaded platform raises in
25 sec
.
All GPTLR:
Unloaded platform raises and
lowers evenly. At the extension plate, platform
must not be more than
1/4”
uneven, from side
to side.
All GPTLR:
Breakaway force to unfold plat-
form is
30 lb-ft
maximum. Breakaway force to
fold platform is
40 lb-ft
maximum.
All GPTLR:
Platform stores securely under
vehicle body
Check if cycle counter works
Decals in correct location and legible
Verify all lights are operational
(For lights supplied by MAXON only)
Platform lights turn
ON
when platform is un-
folded, and turn
OFF
when platform is stowed.
Taillights, stop lights, turn lights, and backup
lights turn
ON
and
OFF
correctly.
NOTE:
The following times are for 55” bed
height, aluminum platform and
fl
ipover, Exxon Univis HVI-13 oil,
& temperature at 70°F. Times are
for reference only and may vary for
larger platforms, smaller platforms,
or temperature changes.
Model:______________________ Date:
____________________
Serial Number: _______________
Technician: _______________
PRE-DELIVERY INSPECTION FORM
Important!
This pre-delivery checklist is to aid the installer in con
fi
rming the proper installation of
this Maxon product. It is not a comprehensive list and does not replace the use of the installation
manual. The installer is responsible for following all instructions in the installation manual.