Service Switch in series 11
Authorized personal can use and test all liftgate functions
directly with the service switch located in the power unit.
In case of failure of the hand or foot controls, the liftgate can be
driven into any position by authorized personal (emergency
function)
Option body lighting in series 11
The clamping strip located on the service switch can be used to connect the body lighting.
To connect the body lighting, connect the lightning cable on the clamp “K+” and the clamp “31”
on the clamping strip or on chassis instead clamp “31”. It is turned on and off with the cabin
switch together with the liftgate and is protected by a 4 Ampere fuse.
Please respect the sequence, KM always last
Fonction
Y3
KM
YA
Y1
Si
Lifting
●
●
●
Lowering
●
●
●
Open / tilting down
●
●
●
●
Closing / tilting up
●
●
●
Body lighting
Body lighting fuse