![Maxon GPC 22 X1 Installation Manual Download Page 26](http://html1.mh-extra.com/html/maxon/gpc-22-x1/gpc-22-x1_installation-manual_1745090026.webp)
Installation manual
Liftgate GPC 22 X-1, Series 11
Document no.: S 20 912 436
26
Version 2021
Function of the adjustment fork
After the installation of the liftgate the two arms must touch the body sill at the same time, and
must be touching the body sill also all the time when platform is normally loaded.
This can be done with the adjustment fork on the right lift arm if an adjustment is necessary. If
the bolt is turned to the right, the lifting arm is tightened more against the rear beam.
A
A
Turning the bolt clockwise the right liftarm will
come closer to the body sill.
Turning counter-clockwise the right liftarm
will stay further away from the body sill.
NOTICE
When finished adjusting or if no readjustment is necessary, make sure that the
adjustment fork bolt
A
is securely tightened (see torque table).
Adjustment fork
A
Summary of Contents for GPC 22 X1