Setup
Connections
maxon motor control
3-48
Document ID: rel6852
EPOS4 Positioning Controller
Edition: May 2017
EPOS4 50/5 Hardware Reference
© 2017 maxon motor. Subject to change without prior notice.
Table 3-34
CAN-CAN Cable
Note
• Consider the CAN master’s maximal bit rate.
• The standard bit rate setting (factory setting) is 1 Mbit/s, automatic bit rate detection is set.
• Use 120
Ω
termination resistor at both ends of the CAN bus.
• For detailed CAN information
separate document «EPOS4 Communication Guide».
CAN-CAN Cable (520858)
Cross-section
2 x 2 x 0.14 mm
2
, twisted pair, shielded
Length
3 m
Head A
Plug
Molex CLIK-Mate, single row, 4 poles (502578-0400)
Contacts
Molex CLIK-Mate crimp terminals (502579)
Head B
Plug
Molex CLIK-Mate, single row, 4 poles (502578-0400)
Contacts
Molex CLIK-Mate crimp terminals (502579)
CAN interface
Standard
ISO 11898-2:2003
Max. bit rate
1 Mbit/s
Max. number of CAN nodes
127/31 (via software/hardware setting)
Protocol
CiA 301 version 4.2.0
Identifier setting
By DIP switch or software