ISSUE
POSSIBLE CAUSE
SOLUTION
Flatwork Scorched or Discol-
ored
1.
If flatwork rinses clean with
a small amount of soap, a
chemical residue is left over
from the wash cycle.
• Adjust the settings of the washer.
2.
If flatwork does not rinse
clean, the temperature is
set too high, the ironing
speed is too slow, and/or
moisture retention from the
washer/extractor is incor-
rect.
• Refer to
3. If rust-colored spots occur
on the flatwork, there is a
condensed wax buildup
under the canopy and/or
the feed table.
• Check and clean any condensed wax
buildup under the canopy and the feed
table.
Flatwork Does Not Dry Cor-
rectly
1. Processing standards are
not being followed.
• To review the directions for setting up
2. Flatwork left in a hamper
for a long time will have an
uneven moisture content.
• Increase heat or decrease ironing speed
SLIGHTLY for linen that feels more
damp.
3. Flatwork run through
washer/extractor with cold
water will have less mois-
ture extracted.
•
Increase final flatwork temperature
from extractor. Refer to
ing Flatwork Before Ironing on page
.
4. Extractor is not removing
enough moisture.
• To review the extraction process, refer to
Conditioning Flatwork Before Ironing
5. TEMPERATURE control is
not working properly.
• Replace the TEMPERATURE control.
Temperature Limit Control Replace-
TOC
INDEX
Summary of Contents for Comet Executive Exec-56-G
Page 1: ...INSTRUCTION MANUAL COMET EXECUTIVE Gas Heated Flatwork Ironer...
Page 42: ......
Page 58: ......
Page 80: ......
Page 164: ......
Page 166: ...SC 2 Motor Circuit 115V 1 Phase SC TOC INDEX TOC...
Page 168: ...SC 4 Motor Circuit 230V 1 Phase SC TOC INDEX TOC...
Page 170: ...SC 6 Motor Circuit 230V 3 Phase SC TOC INDEX TOC...
Page 172: ...SC 8 Motor Circuit 415V 3 Phase SC TOC INDEX TOC...
Page 174: ...SC 10 Motor Circuit 460V 3 Phase SC TOC INDEX TOC...
Page 176: ...SC 12 Main Electrical Panel 115V 1 Phase SC TOC INDEX TOC...
Page 178: ...SC 14 Main Electrical Panel 230V 1 Phase SC TOC INDEX TOC...
Page 180: ...SC 16 Main Electrical Panel 230V 3 Phase SC TOC INDEX TOC...
Page 182: ...SC 18 Main Electrical Panel 460V 3 Phase SC TOC INDEX TOC...
Page 184: ......
Page 185: ...TOC INDEX...
Page 186: ......
Page 187: ...TOC INDEX...
Page 188: ......
Page 189: ...TOC INDEX...
Page 190: ......
Page 192: ......
Page 194: ......
Page 196: ......
Page 197: ...304500 1a TOC INDEX MB TOC...
Page 198: ...TOC INDEX MB TOC...
Page 199: ...TOC INDEX MB TOC...
Page 200: ...TOC INDEX MB TOC...
Page 221: ...3045069 TOC INDEX MB TOC...
Page 222: ...TOC INDEX MB TOC...
Page 223: ...TOC INDEX MB TOC...
Page 224: ...TOC INDEX MB TOC...
Page 229: ...TOC INDEX MB TOC...
Page 230: ...TOC INDEX MB TOC...
Page 231: ...TOC INDEX MB TOC...
Page 232: ...TOC INDEX MB TOC...
Page 236: ......
Page 238: ......
Page 244: ......