Troubleshooting
Comet Executive Gas
6-8
WARNING
Only trained personnel with experience
in gas, electrical or mechanical repair
should troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
NOTE:
Several drive trains are used on the machine. They share common features and can be diagnosed us-
ing the information below. Check the components for the particular drive train being troubleshot.
Drive System Mechanical or
Electrical Error
1. Chain loose or broken.
• Check the chain.
• Adjust or replace; refer to
Tension Adjustment on page 7-23
2. Mechanical component
loose, misaligned or bro-
ken.
• Check that sprocket is properly secured
to shaft:
-Tighten setscrews as necessary.
-Replace shaft key as necessary.
-Replace roll if shaft damaged.
-Check to see if sprocket is missing
teeth. Replace.
• Check and correct any alignment errors.
Replace any component that does not
work smoothly and quietly after align-
ment.
3. An inverter, motor protector
or motor thermal overload
has tripped.
•
For inverter problem, turn machine off
for one minute.
-For motor protector, reset tripped
device.
-For thermal overload, motor must be
allowed to cool until automatic reset.
4. There is an open some-
where in the motor circuit or
a component is defective.
• Check for an open connection in one of
the wires on a 3-phase motor.
• Check for an open connection between
motor and inverter or motor protector.
• Check for an open connection between
the contactor and inverter or motor
protector.
• Check for defective component such as
contactor or motor protector and replace
if necessary.
• Inverter fault. Call factory for service.
• Motor is defective and needs to be
replaced.
TOC
INDEX
Summary of Contents for Comet Executive Exec-56-G
Page 1: ...INSTRUCTION MANUAL COMET EXECUTIVE Gas Heated Flatwork Ironer...
Page 42: ......
Page 58: ......
Page 80: ......
Page 164: ......
Page 166: ...SC 2 Motor Circuit 115V 1 Phase SC TOC INDEX TOC...
Page 168: ...SC 4 Motor Circuit 230V 1 Phase SC TOC INDEX TOC...
Page 170: ...SC 6 Motor Circuit 230V 3 Phase SC TOC INDEX TOC...
Page 172: ...SC 8 Motor Circuit 415V 3 Phase SC TOC INDEX TOC...
Page 174: ...SC 10 Motor Circuit 460V 3 Phase SC TOC INDEX TOC...
Page 176: ...SC 12 Main Electrical Panel 115V 1 Phase SC TOC INDEX TOC...
Page 178: ...SC 14 Main Electrical Panel 230V 1 Phase SC TOC INDEX TOC...
Page 180: ...SC 16 Main Electrical Panel 230V 3 Phase SC TOC INDEX TOC...
Page 182: ...SC 18 Main Electrical Panel 460V 3 Phase SC TOC INDEX TOC...
Page 184: ......
Page 185: ...TOC INDEX...
Page 186: ......
Page 187: ...TOC INDEX...
Page 188: ......
Page 189: ...TOC INDEX...
Page 190: ......
Page 192: ......
Page 194: ......
Page 196: ......
Page 197: ...304500 1a TOC INDEX MB TOC...
Page 198: ...TOC INDEX MB TOC...
Page 199: ...TOC INDEX MB TOC...
Page 200: ...TOC INDEX MB TOC...
Page 221: ...3045069 TOC INDEX MB TOC...
Page 222: ...TOC INDEX MB TOC...
Page 223: ...TOC INDEX MB TOC...
Page 224: ...TOC INDEX MB TOC...
Page 229: ...TOC INDEX MB TOC...
Page 230: ...TOC INDEX MB TOC...
Page 231: ...TOC INDEX MB TOC...
Page 232: ...TOC INDEX MB TOC...
Page 236: ......
Page 238: ......
Page 244: ......