CONTROLLER MENUS: 1Y.3 JOB SETTINGS
7 - 10
D-MAXE with OI-B/OI-N
www.maxcessintl.com
MI 2-296 1 D
Menu 1y.3.y6 ASC
Description
You can use the
ASC menu (Automatic Sensor Control) to
– activate and deactivate the
ASC parameter and
– set up
ASC threshold 1 or 2. These thresholds restrict the
outward visual range of the sensor.
If the D-MAXE system is in "Automatic" mode and the
ASC
parameter is activated, the web is guided as long as it is within
the restricted field of view of the sensor. This is indicated by the
“ASC“ [0010] icon in the display.
If the web leaves the limited field of view of the sensor, guiding
is blocked. This is indicated by the “ASC“ and “Motor locked“
[0030] icon in the display.
Menu
Key sequence for menu
1y.3.y6
:
The menu for the
ASC parameter appears.
Switch to the menus that describe the properties of the
ASC
parameter
1 - Threshold 1 (pos.)
2 - Threshold 2 (neg.)
Guiding working
Guiding locked
1y.3
→
Job Settings
or
1y.3.y6
→
ASC
or
1y
. . .
. . .
. . .