COMMISSIONING
6 - 2
D-MAXE with OI-B/OI-N
www.maxcessintl.com
MI 2-296 1 D
Inbet
riebnah
me.f
m
WARNING:
Do not touch anything on or in the vicinity of the moving parts
while the D-MAXE system is in operation.
This involves the risk of being cut on the web.
There is a danger of body parts being crushed against the
actuator.
To commission the D-MAXE system, make the basic settings
described in the following steps.
Note:
If the system documentation contains "Supplementary Operating
Instructions" for the D-MAXE, the commissioning sequence
given there must be followed.
1. Supply electrical power to the D-MAXE system.When the
system is turned on, the last operating mode to be selected
is active.
2. It may be necessary to change the language for menu
guidance on the operator interface.
)
3. Select the desired drive ("device") with the A key.
Selection of "devices", page 4-11
)
Note:
Each drive must be set separately.
4. If the
Remote Control parameter is set to
ON
, this
parameter must be set to
OFF
.
)
5. Switch the D-MAXE system into Manual mode with the F3
key on the operator interface.
There is no guiding of the web course in Manual mode.
Now the D-MAXE system can be adjusted to the relevant
application.
6. Calibrate the connected sensor/sensors.
Menus 1y.5.1.1 S 01 (X5 /1), page 7-20
and following
pages.