INTRODUCTION
www.maxcessintl.com
CYGNUS
MI 850A316 1 B
Page 6 of 66
2.0
Installation
Model CYGNUS-E is intended for mounting on any flat vertical surface capable of supporting it. See Figure 9 for
dimensions. The CYGNUS-E meets the environmental and mechanical requirements of EN50178. CYGNUS-E
exceeds the environmental degree of protection requirement with an IP65 rating. If the IP65 rating is required in
the final installation, sealing type cable grips should be used for cable entry. Four mounting holes are provided for
attachment of the CYGNUS-E to the mounting surface. The means of attachment should comply with the essential
requirements of the appropriate standard(s) and is the responsibility of the installer.
Model CYGNUS-DIN is intended for installation through a DIN panel opening in a customer panel or enclosure.
The panel itself must provide sufficient strength to support the weight of the CYGNUS-DIN as well as insure the
integrity of the environmental seal. The CYGNUS-DIN maintains a degree of protection of IP65 over its front panel.
It also meets the environmental and mechanical requirements of EN50178. The CYGNUS-DIN mounting clips
found on both sides of the enclosure behind the front panel will accommodate panel thickness of 0.06 inches (1.5
mm) to 0.25 in. (6.9 mm).
Wiring to and from the enclosure must be done with double or reinforced insulation or protective screening which
provides protective separation. All wiring outside either of the CYGNUS enclosures should comply with the
essential requirements of the appropriate local standard(s) and is the responsibility of the installer.
If using a magnetic particle clutch or brake, see Figure 6 to install the Model PS-90 or PS-24 Power Amplifiers
inside the CYGNUS-E enclosure.
Section 2.1 provides a summary of the basic set-up and calibration of the CYGNUS control. Additional features and
options of the CYGNUS control are described later in this manual.