SYSTEM SETUP
www.maxcessintl.com
CYGNUS
MI 850A316 1 B
Page 13 of 66
6.2.3
Remote tension set point/set-up select (optional)
This option allows both the desired tension and the setup number to be set by an external input. The desired
tension input can be either a 0 to 10 VDC analog signal or a remote potentiometer. The analog setup number
select input and can be either a 0 to 10 VDC signal or a remote potentiometer.
(Home Screen)
NOTES:
1. There are (4) assignable inputs
(TB4-2, TB4-2, TB5-1 and TB5-3) on the
CYGNUS and (5) possible inputs. If you
are using “Remote Setup Select”,
“Remote Setpoint”, “Web Velocity” and
“Roll RPM” you must use Velocity/RPM
Method to calculate diameter.
2.
Remote Setpoint Potentiometer
must be calibrated. This is done
during Load Cell Calibration.
The screen will prompt you to
“Adjust remote setpoint device to max.”
Assign which “available”
terminal input will be
used for Remote
Setpoint.
(Use to return to previous screen)
Assign which “available”
See Figure 7 for
terminal input will be
Remote Setup wiring
used for Remote Setup
Select.
See Figure 6 for
Remote Setpoint
Wiring
See Table 2 if setup is being
done via a programmable
logic controller.