SPECIFICATIONS
www.maxcessintl.com
CYGNUS
MI 850A316 1 B
Page 65 of 66
11.0
Specifications
Supply Voltage
115 or 230 volts rms,
10%, 24 VA
Supply Frequency:
50 or 60 cycles per second, sinusoidal
Fuses: F1, F2
1.6 amp, Littelfuse Part No. 21601.6, or
Wickmann Part No. 19194-053-FS
Enclosure
CYGNUS-DIN
Front Panel
IP65 (IEC529)
Enclosure
IP20 (IEC529)
CYGNUS-E
IP65 (IEC529)
Climatic Class:
3K3 (EN60721)
Temperature Range:
Operating
CYGNUS-DIN
0
°
C to 50
C
CYGNUS-E
0
°
C to 40
°
C
Storage
-30
°
C to +80
°
C
Relative Humidity
5% to 85%
Pollution Degree:
2 (IEC664-1)
Altitude:
0 to 2000 m
Compatible Residual
Current Devise Types:
A or B (IEC755)
Worst Case Fault Current:
1.6 amp
Inputs:
Load cell
2.1 millivolts/volt using +5 and -5 VDC (10 VDC)
across one 350 ohm sensor or two 350 ohm sensors
in parallel,
or
100 mVDC, using 5 volts across one 120 ohm full bridge,
or
0 to +10 VDC analog
Diameter
0 to +10 VDC analog
Velocity / RPM
0 to +10 volts analog, or
0.01 to 50,000 pulses per second, 5 VDC or 24 VDC logic
Auxiliary Input
0 to +10 VDC, 1 mADC maximum
E-Stop
switch closure or 5 VDC or 24 VDC logic, 8 mADC maximum
Run/Stop
switch closure or 5 VDC or 24 VDC logic, 8 mADC maximum
Tension Off
switch closure or 5 VDC or 24 VDC logic, 8 mADC maximum
Format
switch closure or 5 VDC or 24 VDC logic, 8 mADC maximum
Splice
switch closure or 5 VDC or 24 VDC logic, 8 mADC maximum
Outputs:
Isolated
0 to +10 VDC, 1 mADC maximum
4 to 20 mADC, 500 ohms maximum
-10 to +10 VDC, 1 mADC maximum
Non-isolated
0 to +10 VDC, 1 mADC maximum
Inverse Diameter
0 to +10 VDC, 1 mADC maximum
Low Tension
DC solid state relays, 100 mADC, 30 VDC maximum or TTL levels
Tension status
DC solid state relay, 100 mADC, 30 VDC maximum or TTL levels
Tension Reference
0 to 1 mADC or 0 to +10 VDC analog
Summary of Contents for Cygnus MAGPOWR
Page 2: ......