SCREEN DEFINITIONS
www.maxcessintl.com
CYGNUS
MI 850A316 1 B
Page 47 of 66
Screen Function
Definition
Diameter sensor type
Toggle to activate diameter sensing capabilities. Select
"Voltage" if your diameter sensor provides a 0 to 10
VDC output. Select "Estimated" to allow the CYGNUS to
estimate the present diameter based upon the
parameters you provide - see also CALIBRATE
INERTIA/ ACCEL COMP. Select "Velocity/RPM" if you
have velocity and RPM sensors present for the same
roll. Select NONE if diameter will be set by a fieldbus.
Diameter, Vel., RPM sensor types
Select to enter analog input screen. This is where you
will configure velocity, RPM, and diameter sensor inputs
for use.
Digital in: (run/stop, e-
stop, splice…)
Select to enter digital input configuration screen. See
also DIGITAL INPUT VOLTS, DIGITAL INPUT MODE
ACTIVE:, RUN/STOP INPUT, SPLICE INPUT, and
TENSION ON/OFF MODE
Digital input mode active
Toggle to select high active or low active as appropriate
Digital input volts
Toggle to select the input voltage for digital control
inputs. See also RUN/STOP INPUT, SPLICE INPUT,
and TENSION ON/OFF MODE
Digital out: (alarm, tension on/off state)
Select to enter digital output configuration screen. See
also DIGITAL OUTPUT MODE, TENSION ALARM
DELAY
Digital output mode
Toggle to set alarm output levels
Display
Select to enter display calibration options
Display rate
Enter a value for the rate in seconds that the digital
display updates. Default value is 1.0 sec.
Disturb level ___%
Enter a value for the disturbance level to be used during
AUTO TUNE; default is 10%. The disturbance level is a
percentage of the present MANUAL LEVEL. See also
AUTO TUNE START / STOP
Dynamic Parameters
Select to enter tuning parameter screens
E-Stop
Display indicates the present mode of operation is
"emergency stop". This mode is triggered when TB3.3
and TB3.2 are opened. Output goes immediately to
100% for UNWIND mode and 0% for all other modes.
Terminals TB3.2 and TB3.3 must be closed and the
connection for TB3.1 and TB3.2 must be toggled to
cancel E Stop mode.
Enter security code to lock
Enter the four digit code desired to limit access to
CYGNUS settings. See also SECURED and
UNSECURED