TENSIONE CA

 

GAMMA  RISOLUZIONE 

PRECISIONE 

200V 

100mV 

±(2,0% di l 
10 cifre) 

750V 

1V 

RISPOSTA: risposta media, calibrata in rms di un'onda sinusoidale 
GAMMA DI FREQUENZA: 45Hz ~ 450Hz PROTEZIONE DA 
SOVRACCARICO: 1000V CC o 750V rms per tutte le gamme. 
 
 

 

CONTINUITÀ CON SEGNALAZIONE ACUSTICA

 

GAMMA 

DESCRIZIONE 

 

 

Il segnale acustico incorporato suona 

se la resistenza 

è inferiore a 30

±

20

Ω 

PROTEZIONE DA SOVRACCARICO  15  secondi  max. 220 V rms. 

 
 

CORRENTE CC

 

 

GAMMA  RISOLUZIONE 

PRECISIONE 

200uA 

100nA 

 

±(1,8% di l 2 
cifre) 

2000uA 

1uA 

20mA 

10uA 

200mA 

100uA 

±(2,0% di l 2 
cifre) 

10A 

10mA 

±(2,0% di l 10 
cifre) 

PROTEZIONE DA SOVRACCARICO: Fusibile 500mA 250V (gamma 10A 
senza fusibili). 
MISURAZIONE CADUTA DI TENSIONE: 200mV 

 

RESISTENZA

 

GAMMA  RISOLUZIONE 

PRECISIONE 

200

Ω

 

0,1

Ω

 

±(1,0% di l 10 
cifre) 

2000

Ω

 

1

Ω

 

 

±(1,0% di l 4 
cifre) 

20K

Ω

 

10

Ω

 

200K

Ω

 

100

Ω

 

2000K

Ω

 

1K

Ω

 

TENSIONE MAX. CIRCUITO APERTO: 3,2V. 

Summary of Contents for 51924

Page 1: ...COD 51924 Multitester digitale MANUALE D USO Digital multimeters USER MANUAL Polimetros digitale MANUAL DE USUARIO...

Page 2: ...nte la misurazione per evitare danni al Multimetro quando il Multimetro funziona a una tensione effettiva superiore a 60V in CC o 30V rms in CA prestare particolare attenzione al pericolo di scossa el...

Page 3: ...ltezza caratteri 05 1999 conteggi Polarit automatica negativa indicata Metodo di misurazione convertitore integrato A D doppio Velocit di campionamento 2 volte al secondo Indicazione di sovraccarico v...

Page 4: ...suona se la resistenza inferiore a 30 20 PROTEZIONE DA SOVRACCARICO 15 secondi max 220 V rms CORRENTE CC GAMMA RISOLUZIONE PRECISIONE 200uA 100nA 1 8 di lettura 2 cifre 2000uA 1uA 20mA 10uA 200mA 100...

Page 5: ...rminali di misura al dispositivo o circuito da misurare 4 Accendere il dispositivo o il circuito da misurare il valore della tensione misurata apparir sul display digitale insieme alla polarit MISURAZ...

Page 6: ...ali relativi a Emettitore Base e Collettore Inserire i terminali negli appositi fori della presa hFE sul pannello frontale 3 Il multimetro visualizzer il valore approssimativo hFE nella condizione del...

Page 7: ...i visualizzazione la tensione Il fusibile raramente richiede la sostituzione e un fusibile bruciato quasi sempre il risultato di un errore operativo Se sul display viene visualizzato la batteria deve...

Page 8: ...nt of high temperature humidity explosive inflammable and strong magnetic field The performance of the Meter may deteriorate after dampened When using the test leads keep your fingers behind the finge...

Page 9: ...uct net weight 108g including battery Multimeters Function Table Modell o CCV CAV CCA OHM hFE BAT 51924 Technical Specifications Accuracies are guaranteed for 1 year 23 5 less than 80 RH DC VOLTAGE RA...

Page 10: ...mA 100uA 2 0 of rdg 2D 10A 10mA 2 0 of rdg 10D OVERLOAD PROTECTION 500mA 250V fuse 10A range unfused MEASURING VOLTAGE DROP 200mV RESISTANCE RANGE RESOLUTION ACCURACY 200 0 1 1 0 of rdg 10D 2000 1 1 0...

Page 11: ...ly depressed 2 RANGE switch to desired DCA position 3 Open the circuit to be measured and connect test leads INSERIES with the load in with current is to measure 4 Read current value on Digital Displa...

Page 12: ...display will read Temperature value NOTE The TP 01 K type thermocouple Max Operating temperature of Probe 250 C 482 F 300 C 572 F short term The sensor supplied with the instrument is an ultra fast re...

Page 13: ...n display it indicates that the battery should be replaced To replace battery Fuse 500mA 250V remove the 2 screws in the bottom of the case simply remove the old and replace with a new one Be careful...

Page 14: ...go durante la medici n para evitar da os en el mult metro Cuando el mult metro trabaja a un voltaje efectivo de m s de 60 V en CC o 30 V en AC se debe tener especial cuidado ya que existe el peligro d...

Page 15: ...tan pronto como aparezca una fuga Una bater a con fugas da ar el mult metro Pantalla m xima LCD 3 d gitos conteo de 1999 0 5 alto Polaridad Autom tico menos indicado m s supuesto M todo de medida dobl...

Page 16: ...r incorporado suena si la resistencia es menor que 30 20 PROTECCI N DE SOBRECARGA 15 segundos m ximos 220 V rms CORRIENTE DC RANGO RESOLUCI N EXACTITUD 200uA 100nA 1 8 of rdg 2D 2000uA 1uA 20mA 10uA 2...

Page 17: ...se est midiendo el valor de voltaje aparecer en la pantalla digital junto con la polaridad del voltaje MEDICI N DE CORRIENTE DC 6 Cable rojo a V mA Cable negro a COM para medidas entre 200 mA y 10 A c...

Page 18: ...de la toma de hFE en el panel frontal 6 El medidor mostrar el valor aproximado de hFE en las condiciones de corriente de base 10 A y V CE 2 8V MEDICI N DE TEMPERATURA 4 RANGE cambie a la posici n TEM...

Page 19: ...y explota casi siempre como resultado de un error del operador Si Aparece en la pantalla indica que la bater a debe ser reemplazada Para reemplazar la bater a y el fusible 500mA 250V retire los 2 torn...

Reviews: