WARNING

 

READ AND UNDERSTAND THIS MANUAL BEFORE USING THE INSTRUMENT

 

Failure to understand and comply with the WARNINGS and operating instructions 
can 

Warning 

 

 To  avoid  possible  electric  shock  or  personal  injury,  and  to  avoid  possible 

damage to the Meter or to the equipment under test, adhere to the following rules:

 

Ø

 

Before using the Meter inspect the case.  Do not use the Meter if it is 
damaged or the case (or part of the case) is removed.  Look for cracks or 
missing plastic.  Pay attention to the insulation around the connectors.

 

Ø

 

Inspect the test leads for damaged insulation or exposed metal.  Check the 
test leads for continuity.

 

Ø

 

Do not apply more than the rated voltage, as marked on the Meter, between 
the terminals or between any terminal and grounding.

 

Ø

 

The rotary switch should be placed in the right position and no any 
changeover of range shall be made during measurement is conducted to 
prevent damage of the Meter.

 

Ø

 

When the Meter working at an effective voltage over 60V in DC or 30V rms in 
AC, special care should be taken for there is danger of electric shock.

 

Ø

 

Use the proper terminals, function, and range for your measurements.

 

Ø

 

Do not use or store the Meter in an environment of high temperature, 
humidity, explosive, inflammable and strong magnetic field.  The 
performance of the

 

Meter may deteriorate after dampened.

 

Ø

 

When using the test leads, keep your fingers behind the finger guards.

 

Ø

 

Disconnect circuit power and discharge all high-voltage capacitors before 
testing resistance, continuity, diodes or hFE.

 

Ø

 

Replace the battery as soon as the battery indicator 

 

appears.  With a low 

battery, the Meter might produce false readings that can lead to electric 
shock and personal injury.

 

Ø

 

Remove the connection between the testing 

 

leads and the circuit being tested, and turn the Meter power off before 
opening the Meter case.

 

Ø

 

When servicing the Meter, use only the same model number or identical 
electrical specifications replacement parts.

 

Ø

 

The internal circuit of the Meter shall not be altered at will to avoid damage of 
the Meter and any accident.

 

Ø

 

Soft cloth and mild detergent should be used to clean the surface of the

 

Meter when servicing. No abrasive and solvent should be used to prevent the 
surface of the Meter from corrosion, damage and accident.

 

Ø

 

The Meter is suitable for indoor use.

 

Ø

 

Turn the Meter power off when it is not in use and take out the battery when 
not using for a long time. Constantly check the battery as it may leak when it 
has been using for some time, replace the battery as soon as leaking 
appears. A leaking battery will damage the Meter.

 

Summary of Contents for 51924

Page 1: ...COD 51924 Multitester digitale MANUALE D USO Digital multimeters USER MANUAL Polimetros digitale MANUAL DE USUARIO...

Page 2: ...nte la misurazione per evitare danni al Multimetro quando il Multimetro funziona a una tensione effettiva superiore a 60V in CC o 30V rms in CA prestare particolare attenzione al pericolo di scossa el...

Page 3: ...ltezza caratteri 05 1999 conteggi Polarit automatica negativa indicata Metodo di misurazione convertitore integrato A D doppio Velocit di campionamento 2 volte al secondo Indicazione di sovraccarico v...

Page 4: ...suona se la resistenza inferiore a 30 20 PROTEZIONE DA SOVRACCARICO 15 secondi max 220 V rms CORRENTE CC GAMMA RISOLUZIONE PRECISIONE 200uA 100nA 1 8 di lettura 2 cifre 2000uA 1uA 20mA 10uA 200mA 100...

Page 5: ...rminali di misura al dispositivo o circuito da misurare 4 Accendere il dispositivo o il circuito da misurare il valore della tensione misurata apparir sul display digitale insieme alla polarit MISURAZ...

Page 6: ...ali relativi a Emettitore Base e Collettore Inserire i terminali negli appositi fori della presa hFE sul pannello frontale 3 Il multimetro visualizzer il valore approssimativo hFE nella condizione del...

Page 7: ...i visualizzazione la tensione Il fusibile raramente richiede la sostituzione e un fusibile bruciato quasi sempre il risultato di un errore operativo Se sul display viene visualizzato la batteria deve...

Page 8: ...nt of high temperature humidity explosive inflammable and strong magnetic field The performance of the Meter may deteriorate after dampened When using the test leads keep your fingers behind the finge...

Page 9: ...uct net weight 108g including battery Multimeters Function Table Modell o CCV CAV CCA OHM hFE BAT 51924 Technical Specifications Accuracies are guaranteed for 1 year 23 5 less than 80 RH DC VOLTAGE RA...

Page 10: ...mA 100uA 2 0 of rdg 2D 10A 10mA 2 0 of rdg 10D OVERLOAD PROTECTION 500mA 250V fuse 10A range unfused MEASURING VOLTAGE DROP 200mV RESISTANCE RANGE RESOLUTION ACCURACY 200 0 1 1 0 of rdg 10D 2000 1 1 0...

Page 11: ...ly depressed 2 RANGE switch to desired DCA position 3 Open the circuit to be measured and connect test leads INSERIES with the load in with current is to measure 4 Read current value on Digital Displa...

Page 12: ...display will read Temperature value NOTE The TP 01 K type thermocouple Max Operating temperature of Probe 250 C 482 F 300 C 572 F short term The sensor supplied with the instrument is an ultra fast re...

Page 13: ...n display it indicates that the battery should be replaced To replace battery Fuse 500mA 250V remove the 2 screws in the bottom of the case simply remove the old and replace with a new one Be careful...

Page 14: ...go durante la medici n para evitar da os en el mult metro Cuando el mult metro trabaja a un voltaje efectivo de m s de 60 V en CC o 30 V en AC se debe tener especial cuidado ya que existe el peligro d...

Page 15: ...tan pronto como aparezca una fuga Una bater a con fugas da ar el mult metro Pantalla m xima LCD 3 d gitos conteo de 1999 0 5 alto Polaridad Autom tico menos indicado m s supuesto M todo de medida dobl...

Page 16: ...r incorporado suena si la resistencia es menor que 30 20 PROTECCI N DE SOBRECARGA 15 segundos m ximos 220 V rms CORRIENTE DC RANGO RESOLUCI N EXACTITUD 200uA 100nA 1 8 of rdg 2D 2000uA 1uA 20mA 10uA 2...

Page 17: ...se est midiendo el valor de voltaje aparecer en la pantalla digital junto con la polaridad del voltaje MEDICI N DE CORRIENTE DC 6 Cable rojo a V mA Cable negro a COM para medidas entre 200 mA y 10 A c...

Page 18: ...de la toma de hFE en el panel frontal 6 El medidor mostrar el valor aproximado de hFE en las condiciones de corriente de base 10 A y V CE 2 8V MEDICI N DE TEMPERATURA 4 RANGE cambie a la posici n TEM...

Page 19: ...y explota casi siempre como resultado de un error del operador Si Aparece en la pantalla indica que la bater a debe ser reemplazada Para reemplazar la bater a y el fusible 500mA 250V retire los 2 torn...

Reviews: