66 Appendix B: Technical information
❐
Output voltage:
—
Min of low: 0 V.
—
Max of low: 0.55 V.
—
Min of high: 2 V.
—
Max of high: 5 V.
■
Trigger input signal (opto-isolated):
❐
Termination: 511 ohms series.
❐
Input current:
—
Min of low: 0
µ
A.
—
Max of low: 250
µ
A.
—
Min of high: 5 mA
1
.
—
Max of high: 20 mA
2
.
❐
Input voltage:
—
Min of low: 0 V.
—
Max of low: 0.8 V.
—
Min of high: 2 V.
—
Max of high: 5 V.
*Abbreviation for Typical value.
1. A Min of 6.3 mA recommended.
2. A Max of 10 mA recommended.