background image

 

PEX-DAx/PIO-DAxU/PISO-DAxU Quick Start Guide                               

ICP DAS CO., LTD. 

WebSite: http:// www.icpdas.com.tw      E-Mail: [email protected] , [email protected] 

 

 

 

 

 

 

 

 

 

 

 

 

 

The package includes the following items: 

 

 

One PEX-DA, PISO-DAxU and PIO-DAxU series board as follows: 

 

PEX-DA series: PEX-DA4, PEX-DA8, PEX-DA16 
PISO-DAxU series: PISO-DA4U, PISO-DA8U, PISO-DA16U 

 

PIO-DAxU series: PIO-DA4U, PIO-DA8U, PIO-DA16U 

 

One Software Utility CD (V5.2 or later) 

 

One Quick Start Guide (This Document) 

 

One CA-4002 D-Sub connector 

 

 

 

 

 

 

 

Step 1:

 

Setup the Windows driver. The driver is located at:   

 

 

The UniDAQ driver supports 32-/64-bit Windows 2K/XP/2003/Vista/7/8; it 
is recommended to install this driver for new user: 

CD: \NAPDOS\PCI\UniDAQ\DLL\Driver 

http://ftp.icpdas.com/pub/cd/iocard/pci/napdos/pci/unidaq/dll/driver/

 

 

   

For PEX-DA4/8/16 

PISO-DA4U/8U/16U 

PIO-DA4U/8U/16U 

 

What’s in the shipping package?

 

Installing Windows Driver

 

English/ Oct. 2013/ Version 1.1

 

 

Summary of Contents for PISO-DA4U

Page 1: ...s PIO DA4U PIO DA8U PIO DA16U One Software Utility CD V5 2 or later One Quick Start Guide This Document One CA 4002 D Sub connector Step 1 Setup the Windows driver The driver is located at The UniDAQ...

Page 2: ...e Next button Step 5 Check your DAQ Card on list then click the Next button Step 6 Click the Next button on the Select Additional Tasks window Step 7 Click the Next button on the Download Information...

Page 3: ...PEX DAx PIO DAxU PISO DAxU Quick Start Guide ICP DAS CO LTD 3 WebSite http www icpdas com tw E Mail service icpdas com service icpdas gmail com Pin Assignments...

Page 4: ...E Mail service icpdas com service icpdas gmail com DIO Test Wiring 1 Use the CA 2002 optional to connect the CON1 with CON2 Analog Output Test Wiring 2 Prepare for device DN 37 optional Wiring termin...

Page 5: ...i meter to VO_0 Pin 0 and then the negative probe of Multi meter to A GND Pin 05 5 Execute the UniDAQ Utility Program This program UniDAQ Utility will be placed in the default path after completing in...

Page 6: ...s com tw E Mail service icpdas com service icpdas gmail com 6 Get DIO function test result Select the Port 0 Check channel 0 2 4 6 6 5 Click Digital Output item 4 Select the Port 0 8 The corresponding...

Page 7: ...nction test result Select the Port 0 Select the 10V 11 Click Analog Output item 10 Type the voltage value 12 13 Click this button 14 PASS 4 995 Check the value on multi meter they should be identical...

Page 8: ...ard Product Page http www icpdas com root product solutions pc_based_io_board pci pio da4 html CA 2002 CA 3710 and DN 37 page optional http www icpdas com products Accessories cable cable_selection ht...

Reviews: