
44
Chapter 2: Powering and connecting to your Matrox Iris GTX
Connecting a 3-wire NPN proximity sensor to an auxiliary input signal
Connect a 3-wire NPN proximity sensor to a Matrox Iris GTX auxiliary input
signal, as shown below.
Equivalent circuit only
Brown wire
Black wire
Blue wire
3-wire NPN
proximity sensor
24V
Sensing
Circuit
AUX IN
_
AUX IN_COMMON
_
Matrox Iris GTX
Sourcing configuration
+
-
Optional because the auxiliary input signals are optically isolated.
Summary of Contents for Iris GTX Series
Page 1: ...Matrox Iris GTX Installation and Technical Reference Manual no Y11537 101 0002 March 21 2022...
Page 6: ......
Page 50: ...50 Chapter 2 Powering and connecting to your Matrox Iris GTX...
Page 72: ...72 Appendix B Technical reference...
Page 99: ...Limited Warranty Refer to the warranty statement that came with your product...
Page 100: ......