Chapter 2: Powering and connecting to your Matrox Iris GTX
Connecting a sinking output device to an auxiliary input signal
Connect a sinking output device to a Matrox Iris GTX auxiliary input signal, as
shown below.
Equivalent circuit only
24V
Sensing
Circuit
AUX IN
_
AUX IN_COMMON
_
OUT
Sinking device
Matrox Iris GTX
Sourcing configuration
+
-
+V
-V
Optional because the auxiliary input signals are optically isolated.