43
9.9 moTor remoVal
CHaPTer 9: ParT rePlaCemeNT GUide
1) Unplug treadmill.
2) remove the front shroud as outlined in Section 9.1.
3) release drive belt tensioner as outlined in Section 9.5.
4) disconnect the motor power cable from the mCb (figure a).
5) Using a 8 mm allen wrench, remove the four motor mounting screws (figure b).
6) lift the motor away from the treadmill (figure C).
7) When reinstalling the motor, make sure the red vibration pad is in place (figure d)
8) auto Calibration must alWayS be run when installing a new motor.
fiGUre a
fiGUre b
fiGUre C
fiGUre d
Summary of Contents for T5X-02