27
8.5 error meSSaGe TroUbleSHooTiNG
error meSSaGe 0x029f
1) CaUSe - error (drive fault report) created by the motor controller - used for aC motors only.
2) SolUTioN:
a. Power unit off / on.
b. Press any UP arrow key to go to engineering mode and press eNTer.
c. Press any UP or doWN arrow key until rPm Parameter is showing on the display (figure a).
d. Press the eNTer key, the display should now show the Parameter number to get the unit to 1.0 MPh / 1.6 KPh and the belt should start (figure B).
e. if the belt does not start, replace the mCb.
f. f. if the Parameter does not show a value, replace the console.
fiGUre a
fiGUre b
error meSSaGeS 0x02b1 and 0x02b2
1) CaUSe - The emergency circuit on the interface board fails (0x02b1) or the emergency circuit on the interface board active (0x02b2).
2) SolUTioN:
a. Check the emergency stop for function.
b. if emergency stop is not working (always open or closed or a short), replace emergency stop switch (figure a).
c. if emergency stop does not resolve issue, replace console.
fiGUre a
CHaPTer 8: TroUbleSHooTiNG