Entrée Bath Gen III
OPERATION MANUAL
01-27-2022
Page 11 of 18
450 East 32
nd
Street PO Box 1022 (68026)
Fremont NE 68025
800-798-5867 Office: 402-564-5867 FAX: 402-563-9102
www.mastercarebath.com
the factory. If you need more solution, press
the button a second time.
h.
If no solution is dispensed from the
dispensing head, open the service door to
access the solutions storage. Check the fluid
level in the one liter bottle. If below the
intake hose, replace with MasterCare’s Bath
Oil or Shampoo per priming instructions
below.
Note:
1.
If you press Bath Oil or Shampoo button for more than
five seconds, it will initiate a pump prime cycle.
2.
The normal pump cycle can finish and turn off before
the five seconds occurs, but it will still enter Prime and
turn back on.
3.
Holding a Button for a longer time will not cause any
problems other than initiating Prime.
4.
Pressing any button while a pump is running will shut
off the pump. This is predominately a safety feature for
the Prime operation.
5.
Pressing multiple buttons at the same time will turn off
any pumps and be otherwise ignored.
6.
A Red LED associated with the pump operation will turn
on when the pump operation is activated.
7.
See the maintenance instructions for the purpose and
function of the Green LED.
Replacing One Liter Jugs & Priming Operation:
a.
Remove the empty bottle of solutions and replace with
MasterCare’s Bath Oil or Shampoo. Remove the cap and seal
under the cap on the bottle of liquid.
b.
Insert the foot strainer attached to the cap with dispensing hose
into the bottle so that the strainer foot is on the bottom of the
bottle. If replacing an empty two-liter container, check the
strainer at the bottom of the strainer. Remove any accumulated
debris that can clog it up.
c.
To prime, push appropriate button for the solution you are
priming for seven seconds.
CAUTION:
Other brand bath oils and shampoos may be used with
the MasterCare System although re-calibration may be required.
However, some products may not be compatible with the system
and may damage components in the system, thereby voiding the
warranty. MasterCare offers an extended warranty with your use
of MasterCare bathing and Cleaning/disinfection products. Please
contact MasterCare customer service @ 800-798-5867 before using
non-MasterCare products in your system.
SHAMPOO
BOTTLE
BATH OIL
BOTTLE