52
User Manual
53
User Manual
Menu
Level 1
Default
Selection
Comment
Disable
48Hz
10 Seconds
Enable
100%
1
9600bps
English
20 seconds
Cancel
Menu
Level 2
Menu
Level 3
Menu
Level 4
Menu
Level 5
Menu
Level 6
Enable
FREQ
6…60 Seconds
Disable
Enable
0…300%
UNDER
FREQ
REACT
RESP
VRT
ENABLE
POW SI
RATE
1…32
1. 2400bps
2. 4800bps
3. 9600bps
1. Chinese
2. English
3. Italian
20…120 seconds
Set time, date and day
Cancel
Confirm
Disable
Enable
set
frequency
(If enabled,
Once the
AC output
frequency
is lower
than this
set value,
the output
power will
start to
decrease).
This is the time it takes for
the exported reactive
power to reach the grid
standard level. This setting
should not be changed and
is set according to the grid
standard.
Voltage-ride-through.
This setting should not be
changed and is set
automatically according to
the grid standard.
This is the rate of change
of the output. This setting
should not be changed and
is set according to grid
standard. 100% means
that the output will hit full
power within 1 minute.
Allows the user to select
the RS485 address for the
COM port.
Allows the user to select
the RS485 serial baud rate
for the COM port.
Allows the user to select
Chinese, English or Italian
language.
Allows the user to select
how long the display back
light remains lit.
Allows the user to set the
time, date and day.
Clears all stored records.
485
Address
Baud
Rate
Language
Backlight
Date/
Time
Clear
REC
Menu
Level 1
Default
Selection
Comment
Menu
Level 2
Menu
Level 3
Menu
Level 4
Menu
Level 5
Menu
Level 6
Old password
New password
Confirm new password
User cannot access
Cancel
Confirm
Only applicable in Italy
Cut off all load then comfirm
Allows the user to change
the programming
password.
Not accessible to user.
Resets the system to
factory default settings.
Only applicable in Italy.
This action must be
performed when the
inverter is externally
connected to the CT.
Before the CT self-check,
the inverter needs to be
connected to the power
grid and the battery. The
backup circuit breaker and
normal load breaker needs
to be disconnected. The CT
self-check takes about
1~5 minutes.
Shows the user what
model of inverter is in use.
Shows the user the serial
number of the inverter.
Shows the user the
firmware version.
Shows the user the active
faults or errors.
Shows the user the battery
modules connected and
connection state.
Shows the user the hours
run of Inverter and Grid
connection.
Shows the number of
times the inverter is
connected to the grid.
Shows the user the total
generated watts and
today's generated watts.
Password
Maintenance
Factory
RESET
Auto Test
CT
self-check
Run:
Grid:
Unit: hours
Times:
History:
Today:
Units: watts
00000
Cancel
INV Module
Module SN
Firmware
Record
BMS Info
Time
stat
Conne
Time
Peak
Power
Inquire
Statistic