4.2 Display and Setting
4.2.1 General settings
After the machine is installed, you can use it by following the steps below. If you have more require-
ments for setting, you can refer to Section 4.3
Press ESC button to enter the setting interface and the default password is 00000.
User Manual
43
User Manual
The energy
generated by the
solar panels will be
used in the
following order:
Feed the home
loads; Charge the
battery and then,
feed into the grid.
When the sun is
not present, the
load will be
supported by the
battery to enhance
self-consumption.
If the power supply
from the batteries
is not sufficient,
the grid will
support the load
demand.
Menu
Level 1
Default
Selection
Comment
Menu
Level 2
Menu
Level 3
Menu
Level 4
Menu
Level 5
Menu
Level 6
Menu
Level 7
Menu
Level 8
This mode is
designed for
time-use mode.
The customer can
set up the desired
charging/dischargi
ng time & power
via the inverter
screen or APP.
Manually forces the
system to charge
the batteries from
the grid.
Manually forces the
system to discharge
to the connected
load.
charge
start1
charge
end1
discharge
start1
discharge
end1
charge
start2
charge
end2
discharge
start2
discharge
end2
100%
(After
charging
to the set
value, the
grid will
stop
charging
the
battery).
00:00 -
23:59
Charge
time
Self
Consume
Peak
SHIFT
Work
Mode
SYS
Setting
Enter
Password
(Default
00000)
SET
UP
Charge
from
Grid
Enable
Enable
Max
SOC
(0% ~
100%)
Disable (default)
Disable
Charge
DISCHG
Time
Setting
set
charging
and
discharging
time
The battery is only
used as a backup
power supply when
the grid fails. As
long as the grid
works, the
batteries won’t be
used to power the
loads. The battery
is charged with the
power generated
by the PV system
or from the grid.
Allows the user to
stop the system
exporting to the
grid. Or, if enabled,
to set the export
power limit.
If Enable is
selected, the user
will be prompted to
enter the power.
CT option is used
for measuring the
system current.
Meter option is
used for measuring
the system current.
Allows the user to
connect an
external inverter to
the system (either
instead of PV, or
in-addition to PC -
Hybrid mode).
Allows the user to
select the country
that the system is
installed in.
Menu
Level 1
Default
Selection
Comment
Menu
Level 2
Menu
Level 3
Menu
Level 4
Menu
Level 5
Menu
Level 6
Menu
Level 7
Menu
Level 8
Disable
BAT Priority
Disable
Enable
Enable
CT
Disable
Zero
export
CT or
METER
AC
Couple
Power
0 ~
Rated
AC
output
power
set the export
power limit
Disable
Enable
Disable
Meter
CT
1. China
2. Germany
3. Australia
4. Italy
5. Spain
6. UK
7. Hungary
8. Belgium
Local
AUS-A
AUS-B
AUS-B
CEI0-21
CEI0-21 ACEA
Grid
STD