21
CV Table
CV
Name
Wert Bereich Funktion
Description
1 Loco Address
3
1..127
CV29-
Bit5=0
7 Version
---
10..99
Softwareversion
read only
8 Manufacturer ID
Reset Function
123
---
123
Attachm. 1
read only
15 Programming Lock
226
0-255
Key for Programming Lock
16 Programming Lock
226
0-255
Lock for Programming Lock
17 Loco Address long
128
128
… 10239
High Bit
CV29-
Bit5=1
18 Loco Address long
0
Low Bit
29
NMRA Configuration
4 Attachm. 1 Basic DCC Settings
31 Signal Address
7
0-7
High Bit (to switch green)
1998
32 Signal Address
206
0-255
Low Bit (to switch green)
62 Contact Output A2
2
0-2
0=deactivated,
1=active,
2=active inverted
110 Function Output FA1
1
0 = light command
1..28 = function command
30 = deactivated
31 = always on
210 Reset Function Key Ax
30
0-28,
30,31
Alle IR-Funktionen rücksetzen
0 = light command
1..28 = function command
30 = deactivated
31 = always on
229 Signal Decoder
Configuration
128
128/
160
Adress in CV 31/32
128 = standard
160 = extended
230 Susi Module Address
1
1-3
255 Decoder Type
226
read only