INSTALLATION
A
D
E
C
F
B
LOCATING YOUR G51 FIREPLACE
Due to high temperatures the Insert should be located out of
traffic and away from furniture and draperies. Provide a minimum
of 48" (1220mm) front clearance to the unit.
This appliance is Listed for Alcove installations, maintain mini-
mum Alcove clearances as follows, minimum ceiling height of
65.5"(1666mm), minimum width of 56.5" (1435 mm) and a
maximum depth of 36"
(915 mm).
a) Cross Corner
d) Island
b) Room Divider
e) Flush with Wall
c) Flat on wall
f)
Flat on Wall Corner
FRAMING
1) The trim kit allows for 1/2" (13 mm) of finish non-combustible facing material. The kit may be installed
directly on and/or against standard combustible building materials.
2) Frame in the Zero Clearance box for the Kit with framing material.
3) For exterior walls, vapour barrier and insulate the Zero Clearance box to the same degree as the rest of the
house, or according to local installation codes.
4) The appliance may be enclosed above the standoffs on the cabinet but the clearances stated on the b-vent
chimney must be maintained.
This unit is not approved for installation
into a mobile home.
Framing Dimensions
A
B
C
839mm 1118mm 428mm
Warning: Combustible materials must not extend
inside the stand-offs on the side, top and rear sup-
ports. For safety reasons do not modify or alter any
components of the 390-900 kit.