MASPORT DIRECT VENT SYSTEM (FLEX)
HORIZONTAL TERMINATIONS ONLY
This flueing system, in combination with the Roma Room Sealed Gas Fireplace, have been tested and listed as a room sealed
heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the flue terminal
Locations diagram.
Masport Direct Vent (Flex) System Termination Kit (Part # 946-513) includes all the parts needed to install the
Roma with a maximum run of 2 feet.
1) 178mm dia. flexible liner (2 ft. length)
2) 100mm dia. flexible liner (2 ft. length)
3) Spring spacers (3)
4) Thimble (2)
5) AstroCap termination cap (1)
6) Screws (12)
7) Tube of Mill Pac (1)
8) Plated screws (8)
9) Screws #8 x 1-1/2" drill point, stainless steel (4)
Note:
1) Liner sections should be continuous without any
joints or seams.
2) Only Flex pipe purchased from Masport may be used
for Flex installations.
3) All joints must be sealed with Mil-Pac.