Installation
7
Installation
Warning!
Read “Safety information” on page 4 before attempting to
install, operate or service this product.
This section describes how to install the luminaire and make connections to
power and control circuits. These procedures must be performed by
qualified professionals.
Weight calculation
The weight of a Rail Light installation can be calculated by allowing 6.5 kg
per meter (4.4 lbs. per ft.) +/- 5%. Through cabling, joints and all other
luminaire components are included in the +/- 5% margin. However, the
weight of cables from distribution boxes to the first luminaire in each group
is not included in this figure and must be obtained from the installation
electrician.
Mounting
Warning!
Check that all fasteners and structures used to mount the Rail
Light can bear the total weight of all devices installed.
Fasteners must be marine grade or acid-resistant, grade 8.8
minimum.
The Rail Light is designed to be mounted on brackets or posts using
suitable hardware. Martin can advise and supply hardware if desired.
Individual luminaires are mounted end-to-end, with power and control
cables running through waterproof connectors from one luminaire into the
next.