background image

7

Understanding Additional Features

High Temperature Protection:

While in the 

HEAT

position, if the room temperature reaches 93 F (34 C),

the thermostat will automatically shut off.  In the unlikely event the room temperature reaches 99 F (37 c), a
mechanical bimetal switch will shut off the thermostat. 

Low Temperature Protection:

While in the HEAT position, if the room temperature drops below 40 F (4

C), the thermostat will automatically initiate a call for heat.  

Compressor Protection: 

To protect the system compressor(s) from damage, the thermostat features a 5

minute delay.  After the cooling system (or heat pump turns off), the thermostat will not allow it to re-start
until the 5 minute delay expires.  A blinking snowflake or flame (heat pump) indicates this feature has been
activated.  Once the 5 minute delay expires, the snowflake will illuminate continuously and the system will
be able to re-start when called upon.

NOTE:

For the purpose of unit installation, this delay can be overridden by pressing the RESET button.

This will erase any programmed settings.

System Reset: 

The thermostat can be reset to factory software settings.  All user entered settings will be

lost.  The reset will also override the 5 minute compressor protection feature.  To reset the thermostat, gen-
tly press the reset button on the front panel using a paper clip or similar small pointed object.

Low Battery Detection:

Low battery power is displayed by the illumination of a battery icon in the LCD.

The thermostat can operate for a period of 2 months once the warning has been initiated.  Two fresh AA
Alkaline batteries should be installed as soon as the warning icon illuminates.

70803-IM  12/18/06  2:10 PM  Page 7

Summary of Contents for 70803

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Non Programmable Electronic Thermostat Heat Cool Model 70803 70803 IM 12 18 06 2 10 PM Page 1...

Page 2: ...t the system control to test the installation This will damage the thermostat and void the warranty This thermostat is equipped with automatic compressor protection to prevent damage due to short cycl...

Page 3: ...ntly depressing the bottom locking tab and swinging the back plate up and away 4 Place the back plate against the wall in the desired mounting location with the thermostat wires protruding from the wa...

Page 4: ...the battery compartment door install 2 AA Alkaline batteries included 14 Remove the clear plastic film from the display Testing The New Thermostat WARNING Do not switch the system to cool if the outd...

Page 5: ...ystem should shut down within several seconds The LCD will again display only the room temperature Programming The User Settings Temperature Differential is factory set at 5 F 0 25 C for both heating...

Page 6: ...et ting of 0 30 or 60 seconds 2 When the desired setting is made release the key and the unit will automatically store the setting after 5 seconds Operating The New Thermostat 1 Set the System switch...

Page 7: ...icates this feature has been activated Once the 5 minute delay expires the snowflake will illuminate continuously and the system will be able to re start when called upon NOTE For the purpose of unit...

Page 8: ...Blinking snowflake flame Allow the 5 minute compressor lock out to expire System turns on off Adjust the differential setting on the thermostat too frequently or A high differential decreases cycle r...

Page 9: ...I is displayed Reduce room temperature or allow a newly installed thermostat to acclimate HI indicates a room temperature reading greater than 90 F 32 C LO is displayed Increase room temperature or al...

Page 10: ...10 Wiring Diagrams Typical 5 Wire System RC RH G Y W B O Inst HEAT 24 VAC TRANSFORMER COM HOT COOL 24 VAC TRANSFORMER COM HOT FAN CONTROL COOL CONTROL HEAT CONTROL 70803 IM 12 18 06 2 10 PM Page 10...

Page 11: ...l Single Stage Heat Pump System RC RH G Y W B O Install Jumper Install Jumper C TR REV VALVE COOL ENERGIZED 24 VAC TRANSFORMER COM HOT FAN CONTROL COMPRESSOR CONTROL REV VALVE HEAT ENERGIZED 70803 IM...

Page 12: ...12 Wiring Diagrams Typical 2 Wire Millivolt System RC RH G Y W B O In C TR COM HEAT CONTROL 24 VAC TRANSFORMER HOT 70803 IM 12 18 06 2 10 PM Page 12...

Page 13: ...13 Wiring Diagrams Typical 4 Wire System RC RH G Y W B O Install Jumper C TR HEAT CONTROL COM 24 VAC TRANSFORMER HOT COOL CONTROL FAN CONTROL 70803 IM 12 18 06 2 10 PM Page 13...

Page 14: ...14 70803 IM 12 18 06 2 10 PM Page 14...

Page 15: ...ho purchased the product from a wholesaler For warranty claims consumers should contact the contractor or dealer who installed the thermostat This warranty and Motors Armatures liability does not incl...

Page 16: ...INSTALLATION AND OPERATING INSTRUCTIONS Non Programmable Electronic Thermostat Heat Cool Model 70803 70803 IM 12 18 06 2 10 PM Page 16...

Reviews: