Troubleshooting

SYMPTOM

CORRECTIVE ACTION

Display is blank

Install 2 fresh AA Alkaline batteries

No heat

Set system switch to 

HEAT

and raise set point above room temperature.

Check thermostat wiring and connections.
Check pilot light or HSI system on furnace.

No cool

Set SYSTEM switch to 

COOL

and lower set point below room temperature.

If snowflake is blinking, allow the 5 minute compressor lock-out to expire.
Check thermostat wiring & connections.

Blinking snowflake/flame

Allow the 5 minute compressor lock-out to expire.

System turns on/off

Adjust the differential setting on the thermostat.

too frequently or

A high differential decreases cycle rate and a low differential increases cycle 

not enough

rate.

Display is not illuminated

Touch the up or down arrow key.  Display will illuminate for 10 seconds.
Change the batteries (display will not illuminate when batteries are low)

Room temperature and

Normal (depending on differential setting).

set point disagree

Check for drafts that could quickly change the room temperature before the 
system is able to correct it.

70803-IM  12/18/06  2:10 PM  Page 8

Summary of Contents for 70803

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Non Programmable Electronic Thermostat Heat Cool Model 70803 70803 IM 12 18 06 2 10 PM Page 1...

Page 2: ...t the system control to test the installation This will damage the thermostat and void the warranty This thermostat is equipped with automatic compressor protection to prevent damage due to short cycl...

Page 3: ...ntly depressing the bottom locking tab and swinging the back plate up and away 4 Place the back plate against the wall in the desired mounting location with the thermostat wires protruding from the wa...

Page 4: ...the battery compartment door install 2 AA Alkaline batteries included 14 Remove the clear plastic film from the display Testing The New Thermostat WARNING Do not switch the system to cool if the outd...

Page 5: ...ystem should shut down within several seconds The LCD will again display only the room temperature Programming The User Settings Temperature Differential is factory set at 5 F 0 25 C for both heating...

Page 6: ...et ting of 0 30 or 60 seconds 2 When the desired setting is made release the key and the unit will automatically store the setting after 5 seconds Operating The New Thermostat 1 Set the System switch...

Page 7: ...icates this feature has been activated Once the 5 minute delay expires the snowflake will illuminate continuously and the system will be able to re start when called upon NOTE For the purpose of unit...

Page 8: ...Blinking snowflake flame Allow the 5 minute compressor lock out to expire System turns on off Adjust the differential setting on the thermostat too frequently or A high differential decreases cycle r...

Page 9: ...I is displayed Reduce room temperature or allow a newly installed thermostat to acclimate HI indicates a room temperature reading greater than 90 F 32 C LO is displayed Increase room temperature or al...

Page 10: ...10 Wiring Diagrams Typical 5 Wire System RC RH G Y W B O Inst HEAT 24 VAC TRANSFORMER COM HOT COOL 24 VAC TRANSFORMER COM HOT FAN CONTROL COOL CONTROL HEAT CONTROL 70803 IM 12 18 06 2 10 PM Page 10...

Page 11: ...l Single Stage Heat Pump System RC RH G Y W B O Install Jumper Install Jumper C TR REV VALVE COOL ENERGIZED 24 VAC TRANSFORMER COM HOT FAN CONTROL COMPRESSOR CONTROL REV VALVE HEAT ENERGIZED 70803 IM...

Page 12: ...12 Wiring Diagrams Typical 2 Wire Millivolt System RC RH G Y W B O In C TR COM HEAT CONTROL 24 VAC TRANSFORMER HOT 70803 IM 12 18 06 2 10 PM Page 12...

Page 13: ...13 Wiring Diagrams Typical 4 Wire System RC RH G Y W B O Install Jumper C TR HEAT CONTROL COM 24 VAC TRANSFORMER HOT COOL CONTROL FAN CONTROL 70803 IM 12 18 06 2 10 PM Page 13...

Page 14: ...14 70803 IM 12 18 06 2 10 PM Page 14...

Page 15: ...ho purchased the product from a wholesaler For warranty claims consumers should contact the contractor or dealer who installed the thermostat This warranty and Motors Armatures liability does not incl...

Page 16: ...INSTALLATION AND OPERATING INSTRUCTIONS Non Programmable Electronic Thermostat Heat Cool Model 70803 70803 IM 12 18 06 2 10 PM Page 16...