manualshive.com logo in svg
background image

FCC Statement 

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC

RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2)
THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

REPLACEMENT COMPONENTS DIVISION

©

CARRIER CORPORATION

www.totaltouch.info

Technical Support: 1-866-90TOUCH (1-866-908-6824)

Physical Dimensions

Case: 5.75” x 4.75” x 1.25”

(145mm x 120mm x 30mm)

Display: 3.625” x 2.125” 

(95mm x 55mm)

HVAC Control Card

Case:4.50” x 3.45” x 0.825”

(114 mm x 87 mm x 21mm)

Electrical Rating

24 volt AC/DC

Class 2 maximum 4 amps

Temperature Accuracy 

+/-1°F degree

Power failure protection safeguards

clock and memory.

Made in China / Printed in China

US PatentS 7,050,026  |  7,028,912  | 6,902,117  |  6,786,421 Other Patents Pending

www.totaltouch.info

Technical Support 1-866-90TOUCH  (1-866-908-6824)

INSTRUCTION MANUAL

P286-1600

2 Heating and 1 Cooling

2 Wire Touch Screen Thermostat with HVAC Control Card

Содержание TotalTouch P286-1600

Страница 1: ... 908 6824 Physical Dimensions Case 5 75 x 4 75 x 1 25 145mm x 120mm x 30mm Display 3 625 x 2 125 95mm x 55mm HVAC Control Card Case 4 50 x 3 45 x 0 825 114 mm x 87 mm x 21mm Electrical Rating 24 volt AC DC Class 2 maximum 4 amps Temperature Accuracy 1 F degree Power failure protection safeguards clock and memory Made in China Printed in China US PatentS 7 050 026 7 028 912 6 902 117 6 786 421 Othe...

Страница 2: ... install application that works in a variety of instal lations where no common wire is avaliable True touch screen technology offers responsive action clear and easy to read LCD display that works in all lighting conditions All with proven reliability backed by the world s largest manufacturer of air conditioning and heating equipment Complete Comfort 3 ...

Страница 3: ... 18 20 Fan Operation Mode 21 Menu Page 22 Date and Time Settings 23 Program Settings 24 Energy Watch 25 Screen Options 26 Vacation Mode 27 Filter Monitor 28 Advanced Features 29 Advanced Features Entry Page 30 31 Configuring your Equipment 32 Setting the Differential 33 Timer Feature 34 Heat Pump 35 Temperature Calibration 36 37 Simple Thermostat Mode 38 Troubleshooting 39 Warranty 40 5 ...

Страница 4: ... For example if the thermostat turns the heating equipment on at 70 degrees F and turns the heating equipment off at 74 degrees F then the differential is 4 degrees F Programmablethermostat Athermostat with the capability of automatically adjusting temperature set point to pre selected settings at pre selected times Setback The automatic alteration of the thermostat control point s by means other ...

Страница 5: ...all 4 Mark the two locations for drilling the 3 16 holes required for the plastic screw anchors 5 Remove the thermostat and drill the two 3 16 holes in these locations 6 Insert the plastic gyproc screw anchors and tighten them securely 7 Make the appropriate wire connections based on the specifications of the household HVAC unit s Please refer to Wiring Table to determine the appropriate wire conn...

Страница 6: ... HVAC CONTROL CARD P286 1600 2 Heating and 1 Cooling for 2 Wire Installation with HVAC Control Card WIRING THE HVAC CONTROL CARD AT THE EQUIPMENT CHOOSE YOUR INSTALLATION 10 ONE AIR CONDITIONER FAN FURNACE AC R C ONE AIR CONDITIONER ONE HEAT FAN AC R C ...

Страница 7: ...C CONTROL CARD 12 FAN FURNACE AC FURNACE 2ND STAGE R C ONE AIR CONDITIONER TWO HEAT FAN STAGE 1 FURNACE AC STAGE 2 FURNACE R C ONE AIR CONDITIONER TWO STAGE FURNACE FAN COMPRESSOR OBW R C ONE HEAT PUMP FAN FURNACE COMPRESSOR OBW R C ONE HEAT PUMP ONE HEAT ...

Страница 8: ...ARD 15 INSTALLING THE HVAC CONTROL CARD 14 FAN SPECIAL FURNACE REMOVE JUMPER C R INDEPENDENT 24VAC SUPPLY FURNACE WITH INDEPENDENT 24VAC SOURCE Then Connect the T1 and T2 to the thermostat You can connect without worry of polarity ...

Страница 9: ...e on steps between the HVAC equipment and the thermostat Upon connection if the COMM Indicator Light is steadily lit it signifies a positive connection If the COMM Indicator Light is pulsing flash flash flash flash and continuously on it signifies that the two wires are open and that the thermostat does not have power Solution Check wire If the COMM Indicator Light is pulsing steady flash on flash...

Страница 10: ...he touch of a finger To access the Control Page simply touch the Home Page Screen anywhere 1 Current Room Temperature 2 Thermostat Control Mode Run Program or Hold Temperature 3 Temperature Control Mode Auto Heat Cool and Off 4 Fan Operation Mode Fan Automatic Fan Intermittent Fan Off 5 Menu Page Access all program features with this button 6 Temperature Control Mode Heat and Cool temperature set ...

Страница 11: ... HVAC equipment you can quickly and easily select the mode of operation Automatic Heat Cool Off Auto choose your heat and cool temperature setpoints the temperature will automatically adjust according to the requirement Heat choose your Heat setpoint Cool choose your Cool setpoint OFF no heating or cooling PROGRAM TEMPERATURE SETPOINTS Choose Heat Heat will appear with a temperature range select y...

Страница 12: ...lTouch Thermostat is effortless with intuitive menu driven programming on our patented touchscreen Enter Date and Time Settings Program 7 days with 4 events per day to improve efficiency and reduce energy costs Energy Watch display kWh consumption as well as the dollar cost of the HVAC System configure this feature in Advanced Settings Clean the Screen without worry Access the Set Screen menu Adva...

Страница 13: ...le with 4 events per day including Fan Mode Select the Day of the Week Select the Event number for example 1 Select the Start Time for example 7 00 AM Choose desired temperature setpoint by raising or lowering the heat cool button Choose the next event for example 2 and repeat the steps Once you have set all the events for one day you may copy the same settings to other days of the week First ensu...

Страница 14: ...matically revert to the Program Settings if you are in Run Program Mode or your can choose to Hold Temperature to raise or lower the setpoint 27 SCREEN OPTIONS CLEAN SCREEN This function allows you to safely wipe and clean the screen with a dampened cloth with out accidentally changing any of the settings it places the TotalTouch screen in a sleep mode for 15 seconds SET SCREEN Your TotalTouch the...

Страница 15: ...e thermostat ADVANCED SETTINGS To begin hold your finger for 5 seconds on the Advanced Settings Button you will hear a beep telling you that you are in the process of entering this feature A warning message will appear CAUTION INCORRECT CONFIGURATION CAN DAMAGE YOUR SYSTEM CONTINUE YES NO ACCEPT YES 29 MENU PAGE FILTER MONITOR Displays filter usage in days and resets filter timer when acti vated t...

Страница 16: ... or emergency contact information Type your message in using the keyboard upon completion choose OK Set the number of months after which you with the message to appear Touch the home or menu icon to exit 31 ADVANCED SETTINGS WELCOME 1 HOME BUTTON Returns you to the Home Page at anytime remember you will have to re enter through the ADVANCED SETTINGS button 2 DAYLIGHT TIME Choose Daylight Time On o...

Страница 17: ...NT IMPORTANT BY INADVERTENTLY MODIFYING COMPRESSOR AND FURNACE SETTINGS YOU MAY SERIOUSLY DEGRADE SYSTEM PERFORMANCE CHOOSE SYSTEM HEATING AND OR COOLING EQUIPMENT REMEMBER ALL YOU NEED TO DO IS TOUCH THE BUTTON WITH YOUR FINGER 1 Choose Heat Pump 2 Stage Heat Pump Air Conditioning No Compressor please review the wiring table and diagram for wiring instructions 2 Choose Furnace Off No Furnace Elec...

Страница 18: ...ome gas or oil furnaces 35 ADVANCED SETTINGS TIMER FEATURE Specify the number of minutes for which Stage 1 will function until Stage 2 is acti vated to help raise or cool temperature if the temperature set point is not reached This unique function avoids excess compressor wear in the case where the neces sary temperature set point is not met through setting of the Staging Differentials Set to 00 t...

Страница 19: ...0 No Correction Required 0 5 1F 5C 1 0 2F 1C 1 5 3F 1 5C 2 0 4 F 2 0C 2 5 5F 2 5C 3 0 6F 3 0C ADVANCED SETTINGS CALIBRATION 37 CALIBRATION OF TEMPERATURE Your TotalTouch Thermostat is rated for an accuracy of 1 degree with temperature If you have determined due to drafts sunlight or other environmental factors that your thermostat needs calibration follow this easy guide Common causes of off set a...

Страница 20: ... the cover plate press the reset button located in the bottom right corner as soon as the message touch to reset password appears touch the screen your PIN will be erased and the ther mostat will unlock 39 SIMPLE THERMOSTAT MODE TOTALTOUCH CAN ALSO FUNCTION AS A NON PROGRAMMABLE THERMOSTAT AFTER IT HAS BEEN CONFIGURED To enable Simple Mode press the reset button take off the thermostat face plate ...

Страница 21: ...rs from the date of the original purchase Exclusions This warranty excludes 1 physical damage to the surface of the product including cracks or scratches on the touch screen or outside casing 2 damage caused by misuse neglect improper installation unauthorized attempts to open repair or modify the product or any other cause beyond the range of intended use 3 damage caused by accident fire power ch...