40
F5 ( SETUP )Screen : PARAMETER
MARK SPEED : Real speed of marking pin.
In case the marking speed is too higher, distance between each dot of cha. become wider
or marking of cha. can be dented.
Refer to below chart and set up the parameter.
Marking pin.
LP-06 , LP-10 , LP-10P LP-Series
PH-16 PH-Series
Effective area
800 ~ 1200
2000 ~ 2300
Proper value
1000
2000
<Normal speed> <In case the MARK SPEED is faster
as compared marking pin.>
MOVE SPEED : Moving speed except for marking
--> Default value of MOVE SPEED is [12000]. In case you set it up higher,
marking location can be changed. You had better keep this value if possible.
ACCEL. RATE : Acceleration rate of motor.
--> Default value of Acceleration rate for motor is [0100].
In case marking location is changed or moving speed of marking pin is too fast,
you can make it..
F1 : M_MENU F2 : A_MARK F3 : EDIT F4 : FILE
F5 : SETUP F6 : TEST F7 : LOAD F8 : COMM
MARK SPEED [ 02000 ]
Use PLC Sequence table ? [ Y ]
Echo mark data to host ? [ Y ]
Move X then Y to offset ? [ Y ]
Move Y then X to home ? [ Y ]
[ SETUP MODE]
CUSOR_MOVE : ENTER F5 : DATE CODE SET
MOVE SPEED [ 12000 ] ACCEL. RATE [0100 ].
X MOTOR [ 10000 ] STEPS/100MM.
Y MOTOR [ 10000 ] STEPS/100MM.
SOL. DN DLY [ 00020 ] SOL. UP DLY [ 00020 ]
END OUT DLY [ 01500 ]
1
2
5
4
8
6
3
7
9
10
12
11
1
2
3
Summary of Contents for MCU-100N
Page 8: ...8 F1 MANUAL MARK MODE...
Page 10: ...10 F2 AUTO MARK MODE...
Page 35: ...35 F4 DATA MODE...
Page 39: ...39 F5 SETUP MODE...
Page 47: ...47 F6 TEST MODE...
Page 49: ...49 F7 FILE LODE MODE...
Page 52: ...52 F8 COMMUNICATION MODE...
Page 59: ...59 How to Create PLT file by standard AUTO CAD 2006...
Page 73: ...73...
Page 79: ...79...
Page 80: ...80...
Page 94: ...94 How to Modify the data of block and modify the time of the controller...