41
X MOTOR [10000] steps/100mm. : Standard: 10000purse per 100mm
If the value of X MOTOR [10000] STEPS/100MM is changed, Marking machine may work
incorrectly because the figure of marking machine is wrong. Do not modify.
MK-100BS , MK-85BS , SI-120 - > STEP [ 25000 ]
Another all other marking head그 -> STEP [ 10000 ]
Y MOTOR [10000] steps/100mm. : Standard: 10000purse per 100mm
If the value of X MOTOR [10000] STEPS/100MM is changed, Marking machine
may work incorrectly because the figure of marking machine is wrong. Do not modify.
MK-100BS , MK-85BS , SI-120 - > STEP [ 25000 ]
Another all other marking head그 -> STEP [ 10000 ]
SOL. DN DLY : The delay time of sol. Valve when the marking is started. (Default value [0020] )
SOL. UP DLY : The delay time of sol. Valve when the marking is finished. (Default value [0020] )
< In case the value of SOL. DN DLY is small > <In case the value of SOL. UP DLY is small. >
-> Make it the value of SOL.DN DLY and SOL UP DLY higher a little by a little.
END. OUT DLY : Output the
“
END
”
signal after marking and keep the output value during 1.5 sec.
Unit of delay [01500] is 0.001sec.
USE PLC SEQUENCE TABLE? : Default value is [Y]. Make it [N] in case you use multi block.
4
5
6
7
8
9
Summary of Contents for MCU-100N
Page 8: ...8 F1 MANUAL MARK MODE...
Page 10: ...10 F2 AUTO MARK MODE...
Page 35: ...35 F4 DATA MODE...
Page 39: ...39 F5 SETUP MODE...
Page 47: ...47 F6 TEST MODE...
Page 49: ...49 F7 FILE LODE MODE...
Page 52: ...52 F8 COMMUNICATION MODE...
Page 59: ...59 How to Create PLT file by standard AUTO CAD 2006...
Page 73: ...73...
Page 79: ...79...
Page 80: ...80...
Page 94: ...94 How to Modify the data of block and modify the time of the controller...