3.4 What has to be done if the covering does not work electrically?
WARNING!
It is forbidden to open the Control Box by removing the bottom cover.
Tampering will void the warranty.
3.4.1 Check and replacement of the internal fuse in emergency case
Before replacing the internal fuse, verify that the external one placed on the positive pole terminal (+) of the battery has not
blown. Otherwise, that fuse needs to be replaced.
IMPORTANT INFORMATION FOR USER SAFETY
The replacement of the internal fuse in emergency case should be executed by the operator only as an
exception. It is important to contact as a matter of priority, if the emergency situation allows it, the local
installer for getting detailed information about the procedure to apply.
WARNING!
Before opening the cover of the contacts of the Control Unit, disconnect the battery to isolate the unit.
WARNING!
This procedure must be absolutely carried out by qualified personnel to avoid invalidation of warranty!
1. Using a suitable screwdriver, loosen the screws on the sides of the cable cover on the left side of the Control Box.
2. Remove the cover while taking care not to damage its gasket.
3. Replace the blown fuse (F).
4. Wait at least 8 hours before reclosing the cover, as the gasket needs a sufficient time to recover it shape. When closing
the cover, be careful not to damage the gasket.