OPERATING INSTRUCTIONS
Always depressurize
the entire system,
disconnect all power
sources and lockout/
tagout all components
before any maintenance
or troubleshooting is
attempted. Failure to
comply with the above
warning could cause
electrical shock and
inadvertent activation of
equipment resulting in
death or serious injury.
W-562
Reset Production Timers
Daily Production Timers:
1) Open Cover (1).
2) Select display to reset. Push and hold correlating Reset Button (2) wait three seconds
then release. This will reset Daily Production Timer (3) for one operator. Repeat
procedure for other operators.
1
5
4
2
3
Total Production Timer:
1) Open Cover (1).
2) Insert key into Key Switch (5).
3) Turn key clockwise and hold for 3 seconds.
4) Turn key back to vertical position and remove from Key Switch (5). This will reset Total
Production Timer (4).