68
5-4 PoE Auto Checking
This page allows the user to specify the auto detection parameters to check the linking status
between PoE ports and PDs. When it detected the fail connect, will reboot remote PD
automatically.
Web Interface
To configue Power over Ethernet Auto Checking in the web interface:
1. Click PoE Management and PoE Auto checking.
2. Enable the Ping Check function.
3. Specify the PD’s IP address, checking startup time, interval time, retry time, failure action
and reboot time.
4. Click Apply to apply the change.
Figure 5-4: The PoE Auto Checking
Parameter description:
Ping Check :
Enable Ping Check function can detects the connection between PoE port and power device.
Disable will turn off the detection.
Port :
This is the logical port number for this row.
Ping IP Address :
The PD's IP Address the system should ping.
Startup Time :
After startup time, device will enable auto checking. Default: 30, range: 30-60 sec.
Interval Time(sec) :
Device will send checking message to PD each interval time. Default: 30, range: 10-120 sec.
Retry Time :
When PoE port can't ping the PD, it will retry to send detection again. When the third time,
Summary of Contents for 94-1518PF
Page 7: ...viii Revision History Release Date Revision Initial Release 2017 01 20 A1 ...
Page 14: ...5 Figure 2 Set system information ...
Page 53: ...44 Reset Click to undo any changes made locally and revert to previously saved values ...
Page 57: ...48 Click to refresh the page Clear Clears the counters for the selected port ...
Page 113: ...104 Reset Click to undo any changes made locally and revert to previously saved values ...
Page 162: ...153 ...
Page 205: ...196 Reset Click to undo any changes made locally and revert to previously saved values ...
Page 244: ...235 Click to undo any changes made locally and revert to previously saved values ...