65
5-2 PoE Status
This page allows the user to inspect the current status for all PoE ports.
Web Interface
To Display
PoE Status in the web interface:
1.
Click PoE Management and PoE Status
2.
Scroll “Auto-refresh” to on/off.
3.
Click “Refresh” to refresh the port detailed statistics.
Figure 5-2: The PoE Status
Parameter description:
Local Port :
This is the logical port number for this row.
PD Class :
Each PD is classified according to a class that defines the maximum power the PD will use.
The PD Class shows the PDs class.
Five Classes are defined:
Class 0: Max. power 15.4 W
Class 1: Max. power 4.0 W
Class 2: Max. power 7.0 W
Class 3: Max. power 15.4 W
Class 4: Max. power 30.0 W
Power Allocated :
The Power Allocated shows the amount of power the switch has allocated for the PD.
Power Used :
The Power Used shows how much power the PD currently is using.
Current Used :
The Power Used shows how much current the PD currently is using.
Priority :
The Priority shows the port's priority configured by the user.
Port Status :
Summary of Contents for 94-1518PF
Page 7: ...viii Revision History Release Date Revision Initial Release 2017 01 20 A1 ...
Page 14: ...5 Figure 2 Set system information ...
Page 53: ...44 Reset Click to undo any changes made locally and revert to previously saved values ...
Page 57: ...48 Click to refresh the page Clear Clears the counters for the selected port ...
Page 113: ...104 Reset Click to undo any changes made locally and revert to previously saved values ...
Page 162: ...153 ...
Page 205: ...196 Reset Click to undo any changes made locally and revert to previously saved values ...
Page 244: ...235 Click to undo any changes made locally and revert to previously saved values ...