2

INSTALLATION GUIDE 

RPFS

 
 

Adapter Tee keyway fittings are available in: 

 

1.  PVC Class 18 Cat. 19 Slip tees (F-glue-ends) pressure pipe 
     Sizes:  20, 25, 32, 40, 50, 65, 80 & 100 mm. 
     PVC high pressure saddle clamps: 40, 50, 80 and 100mm. 
2.  Galvanized Iron threaded connections: 
     BSP (F): pipe sizes 25, 32, 40 & 50 mm;   
     BSP (M) pipe sizes 80 & 100mm. 
3.  Gunmetal  BSP(m) threaded connection end  pipe tube tees  20 mm.  
4.  Polypipe saddle clamps in pipe sizes 40, 50, 63, 75, 90, 110 mm 
5.  PVC saddles 40, 50, 80 and 100mm. 
6.  Stainless steel 25, 32, 40 & 50mm, larger sizes fabricated on request. 
7.  FOR PIPE SIZES 110mm  and larger refer to the RPFS-LS model 

 

**Further custom made fittings are available on request. 

 

Use ManuFlo 

BSPB, BSPB-LS 

(Long Stem) Brass or 

BSPSS

 Stainless Steel 

pipe adapter keyway nipple - with locknut, which has a 1” OD BSP thread for 
screwed insertion into 1”(female BSP) half-sockets which can be welded 
directly to pipe, the BSPB fittings can be coupled to any 1” BSP female entries 
including saddle clamps.  

 

Installation Conditions 

 

IMPORTANT

: A minimum of 10x pipe diameter before (upstream of)  the 

sensor and at least 5x pipe diameter after sensor of straight pipe section 
must be fitted, with no bends, reductions, enlargements, restrictions, valves 
etc within this section. This will help eliminate flow turbulence to ensure  
optimum accuracy performance. 

 

The RPFS sensor must measure in a full pipe flow section. 

 

Can be installed in a horizontal, inclined or vertical pipe position. 

     (Note: If mounted in horizontal or inclined pipe, make sure   
     insertion position of sensor is at top or 45

 from top,  not on the underside). 

 

 

 

 

 

 

 

 

Selection of pipe diameter:                                                         

(For best results, use the table below):

 

Pipe size 

Flowrange (Litres/min) 

Pulses/Litre 

(mm) 

Min 

Max 

(approx.) 

(1)(2)

20 

13 

160 

116 

25 

20 

250 

75 

32 

30 

410 

46 

40 

50 

640 

30 

50 

90 

1000 

20 

63 

132 

1580 

11.7 

65 

120 

1690 

12 

75 

180 

2250 

8.3 

80 

190 

2560 

7.3 

90 

244 

3240 

5.7 

100 

300 

4005 

4.6 

110   (-LS) 

343 

4845 

3.8 

125  (-LS) 

426 

6255 

3.0 

140  (-LS) 

516 

7850 

2.4 

150  (-LS) 

600 

9010 

160  (-LS) 

650 

10200 

1.8 

200  (-LS) 

950 

16000 

1.16 

250  (-LS) 

1480 

25000 

0.7 

 

 

ELECTRICAL INSTALLATION/DATA  

Cable connection: 

 

 

RPFS-P

#

     

Black   =  Pulse 

 

     Brown 

      

=  + 5-30 VDC 

 

     Blue    

    

=  O.V. ground/shield 

looking at 

plug on

RPFS-P sensor

Brown

(5-30 VDC)

Black

(Pulse)

Blue

(Ground)

looking at 

socket on

RPFS-P cable

Brown
(5-30 VDC)

Black
(Pulse)

RPFS-H

#

     White  =  Pulse 

  

     Red    

 

=  + 5-30 VDC 

 

     Shield  =  O.V. ground/shield  

 

# If connecting to non-ManuFlo equipment, a 2K2 pull-up resistor 
may be required between (+) and Pulse. 

 

For extra cable length, use shielded cable only! 

 

      WARNING: To avoid electrical interference the RPFS-H and RPFS-L 
should not be installed within 30cm of any AC fields, otherwise 50Hz 
could be detected and create oscillations. 
 

(1)

 

For >315mm diameter pipes:  

Pulses per Litre = 50273  /  [ (Pipe diameter in mm) 

2.016 

]

 

 

(2)

 

NOTE:

 Due to gravitational forces, the pulse output value can differ 

up to 6% between a vertical flow that is upwards or downwards. Where 
possible, perform a calibration check to determine pulse rate given the 
pipe diameter and flow conditions. Once calibrated, meter will give linear 
and repeatable results within the flow range 

Installing Into Existing Pipe Lines

FIG.1 

IMPORTANT: 

Summary of Contents for ManuFlo ME3000-RPFS

Page 1: ...flowmeter as per the installation guide found on the flowmeter brochure Install the Rota Pulse paddlewheel sensor RPFS P in a straight pipe section with the same diameter pipe as the adaptor tee section with 10x diameter before and 5x diameter after the sensor with no elbows reducers valves or restrictions within this pipe run Where the sensor is housed the pipe must be full when measuring D Use s...

Page 2: ...nd continuously if an error occurs With the ME3000 Batch Controller using the same instrument housing and the same 10 pin Weidmuller receptacle plug as other ManuFlo Batch Controller models changeover or upgrade is instant with no rewiring necessary It can be easily interfaced with PLCs through the optional computer control interface thus incorporating the controller s safety features and providin...

Page 3: ...nfiguration value is diplayed entering a new value via the keypad causes the display value to change and flash Then pressing SET locks in the new value or pressing CANCEL reverts value to its original setting and the display digits stop flashing Use the up down arrows buttons to step through more configuration settings or press CANCEL for 2 seconds to exit to the SET RDY display CALIBRATION 1 The ...

Page 4: ...nel Eagle etc PLCs MC 4 pin PLC Computer Command Start Stop Reset interface plug MC2 2 pin plug for scaled open collector pulse output Includes 4 pin external command Start Stop Reset interface plug e g ME3000 is the standard Batch Controller 240vac powered without any of the options whereas ME3000 MC2 is an ME3000 Batch Controller with a scaled open collector pulse o p and external Start Stop Res...

Page 5: ...tion to larger size pipes is possible depending on pipe wall thickness alternatively the Long Stem LS versions with adaptors are then used With only one moving part and limited intrusion into the pipe and combined with its flow through design the RPFS allows accurate measurement of liquid flows with virtually no head losses Each of the 4 blades of the rotor paddlewheel extends approximately one ce...

Page 6: ...G 6 1 Unscrew the black PVC locking cap anti clockwise 2 Hold the neck of the Tee piece in your left hand grasp the RPFS body with your right hand and turn slowly anti clockwise until the sensor hydraulically raises out of slot then pull upwards out of the socket never by the cable When returning the sensor to nipple adaptor insert so the keyway and slots line up then then push down until they loc...

Page 7: ...e If mounted in horizontal or inclined pipe make sure insertion position of sensor is at top or 45 from top not on the underside Selection of pipe diameter For best results use the table below Pipe size Flowrange Litres min Pulses Litre mm Min Max approx 1 2 20 13 160 116 25 20 250 75 32 30 410 46 40 50 640 30 50 90 1000 20 63 132 1580 11 7 65 120 1690 12 75 180 2250 8 3 80 190 2560 7 3 90 244 324...

Page 8: ...25 LS 140 mm SC140 LS 150 mm PVC150SC LS SCP150 LS SC160 LS 160 mm SCPE160 LS SC160 LS 200 mm PVC200SC LS SCP200 LS SC200 LS 225 mm SCPE225 LS SC225 LS 250 mm SCP250 LS SC250 LS 280 mm SC280 LS 300 mm PVC300SC LS SCPE300 LS SC315 LS Galvanised iron threaded ends BSP female 2000 kPa Note 25mm can be supplied with straight pipe sections already fitted Part GAL25 T2 PVC T piece Class 18 Cat 19 Glue i...

Page 9: ...4 ME3000 ME995 wiring with RPFS or other powered flowmeters ...

Page 10: ...5 ME3000 ME995 wiring with RPFS or other powered flowmeters ...

Page 11: ...6 PLUMBING INSTALL options guide for RPFS or other ManuFlo flowmeters ...

Page 12: ...7 ...

Page 13: ...blem Calcium buildup on wheel soak in diluted acid Warn bushes Backflow alarm Non return valve faulty jammed open Clean service or replace after batch complete Solenoid valve not properly closed damaged seal faulty solenoid Batch target display counter Flowrate too fast excessive overflow Turn down gate valve to restrict flowrate counts past batch selection or set preact overflow deduct function t...