Operator’s Manual
Self-Propelled Scissor Lift
Version 1
31
To Position Platform
1.
Type A/B controller
: press the lift function enable button. The indicator light must be on.
2. press the lift function enable button. The indicator light must be on.
3. Press and hold the function enable switch on the control handle.
4. Move the control handle forward/backward to raise/lower the man platform.
To Steer
1.
Type A /B controller
: press the drive function enable button.The indicator light must be on.
2. Press and hold the function enable switch on the control handle.
3. Turn the steering wheels to the left/right by pressing the thumb rocker switch located on the top of the
control handle to the left/right.
To Drive
1.Type A /B controller
: press the drive function enable button. The indicator light must be on.
2.Use the drive speed selector button to select slow or fast speed.
3.Press and hold the function enable switch on the control handle.
4.Slowly push the control handle forward/backward to drive the machine forward/backward.
5.Increase speed: Slowly move the control handle off center.
Decrease speed: Slowly move the control handle towards center.
Stop: Return the control handle to center or release the function enable switch.
Note
: Machine travel speed is restricted when the platform is raised more than 5 ft (1,5 m) from its
stowed position.
Driving On a Slope
Determine the vertical and lateral slope ratings for the machine and determine the slope grade. Refer
to the Specifications for vertical and lateral slope ratings of the machine.
Note
: Slope ratings are subject to ground conditions and adequate traction.
1. If the slope exceeds the maximum vertical or lateral slope rating, the machine must be winched or
transported up or down the slope. See Lifting Instructions and Transport Instructions.
Tilt Indicator Light On (Type A Controller) / Tilt Error Code Shown (Type B Controller)
If the buzzer alarm and LCD readout screen shows
”LL” on the
Type A
platform controller / the tilt error
code on the type B platform controller is shown
”LL” and the buzzer alarm, there is a risk for tipping over
and no functions (except lowering of the platform) will operate.
1. Completely lower the platform.
2. Drive the machine to a level surface before continuing operation.
Overload Indicator Light On (Type A Controller) / Overload Error Code Shown (Type B
Controller)
If the overload indicator light on the
Type A
platform controller is on, the load on the platform is
between 95% and 100% of the maximum allowed load. No functions (except lowering of the platform)
will operate. An alarm will sound.
1. Completely lower the platform.