Turbo timer instructions
The system has two turbo timer features. Firstly it has its own on-board turbo timer system, and secondly it has an
interface so is compatible with external turbo timers.
On-board turbo timer
On most vehicles the AVS S-Series can be set up to run the on-board turbo timer by simply connecting the ignition
immobiliser wires that would normally be connected to the key side of the cut (IM2A) to +12V main power feed as
shown in the diagram below.
The IGN sense wire remains on the key side of the ignition wire while the remaining immobiliser wires (IM2B) are
connected to the engine side of the ignition wire. Many vehicles have dual ignition wires to run cooling fans. You
must ensure the cooling fans continue to run when the vehicle is running on the turbo timer, you may need to hook
up the second ignition wire relay as per next page. Note: IM2A MUST BE CONNECTED TO +12V MAIN POWER
FEED.
Wiring instructions:
How to set up the on-board turbo timer:
1.
Install the alarm as normal except connect the ignition immobilisers and IGN input to the alarm as shown in the
diagram.
2.
Ensure all doors, bonnet and boot are closed.
3.
Turn the ignition on, off and on then press the
button 16 times. The indicators, LED and siren will flash or
chirp upon each press of the button.
4.
Now turn the ignition off. The siren should chirp the current run time setting to indicate that the programming
mode has been entered.
5.
Pressing the
button will increment the run time. There are four levels, each level is indicated by the
number of chirps. See table below.
Number of chirps
Turbo timer run time
1
1 minute
2
2 minutes
3
4 minutes
4
10 seconds