92
Par
t Number
STH02
6 2/12
E11
Refig Fault
Refrigeration System (Refrig
Fault)
The compressor discharge temperature did not increase by at least 10 F, and the evaporator
temperature did not decreased by at least 10 F - Measured from Refrigeration Start up to Two Minutes
into the Freeze cycle.
E12
Curtain Fault
Curtain Switch open for more
than 12 hours (Curtain Fault)
The ice machine is set to ice making and remains in bin full condition for more than 12 hours.
The curtain switch is open or curtain is off.
E13
Spare
E14
Spare
E15
Low Liq Temp
Low amb control fault durring low
amb
If the liquid line temperature drops below 60 F for any period exceeding 1 minute (contiguous) during the
the freeze cycle.
E16
Rmt Cnd Fault
Remot Condenser Fault
If the liquid line temperature drops below 40 F, or exceeds 140 F for more than 1 continuos minute
during the freeze cycle.
E17
Spare
E18
Spare
E19
ITP Fault
Ice Probe (ITP)
The monitored Frequencies is out of the appropriate range (Probe unplugged or problem with
microphone).
E20
WTR Fault
Water System Fault
Any of the following:
1) Sensing high water probe and not low water probe = Water fault.
2) The Evaporator outlet temperature is less than -10°F @ 6 Minutes into freeze.
3) The Water probe is satisfied at the end of harvest.
E-Log Display Text
Error Description
Definition
Detail Event Log Service Definition
Indigo_Model_Tech.book Page 92 Monday, February 20, 2012 1:17 PM
Summary of Contents for QuietQube Indigo Series
Page 2: ......
Page 22: ...22 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 36: ...36 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 60: ...60 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 110: ...110 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 115: ...Part Number STH026 2 12 115 This Page Intentionally Left Blank ...
Page 116: ...116 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 157: ...Part Number STH026 2 12 157 This Page Intentionally Left Blank ...
Page 158: ...158 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 197: ...Part Number STH026 2 12 197 This Page Intentionally Left Blank ...
Page 209: ...Part Number STH026 2 12 209 This Page Intentionally Left Blank ...
Page 216: ...216 Part Number STH026 2 12 USING PINCH OFF TOOL ...
Page 220: ...220 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 233: ...Part Number STH026 2 12 233 I0670C I0870C I1070C I1270C QuietQube Remote Air cooled 1 3 Ph ...
Page 234: ...234 Part Number STH026 2 12 IB0690C IB0890C IB1090C QuietQube Remote Air cooled 1 3 Ph ...
Page 235: ...Part Number STH026 2 12 235 II1400 I1800 I2170 QuietQube Remote Air cooled 1 3 Ph ...
Page 236: ...236 Part Number STH026 2 12 ICVD2095 QuietQube Remote Air cooled 3 Ph ...
Page 243: ...Part Number STH026 2 12 243 This Page Intentionally Left Blank ...
Page 244: ...244 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 245: ...Part Number STH026 2 12 245 This Page Intentionally Left Blank ...
Page 246: ...246 Part Number STH026 2 12 This Page Intentionally Left Blank ...
Page 247: ......