OPERATING CONTROLS AND PROCEDURES
TMS800E13 OPERATOR MANUAL
3-16
Published 02-06-2014, Control # 495-00
Center Front Stabilizer Overload Indicator (22)
The lamp will turn on red if the overload pressure switch is
active high.
Module Offline Indicator (23)
This indicator lamp will turn on red whenever any module
either loses power or communication with the Master
Module. The lamp will also turn on if the Engine Fault Code
Chart is not loaded on the crane.
Electrical Diagnostic Indicator (24)
This lamp will turn red whenever any output on the crane
control system experiences an abnormal operating condition
(such as, open, short to battery, short to ground, over
current).
Crane Control Status Indicators (25)
The crane control status indicators located along the right-
hand side have three possible states: function disabled
(gray), function inactive (blue), and function active (orange).
The functions listed from top to bottom are Swing, Tele, Lift,
Main Hoist, and Aux Hoist (only visible if the Aux Hoist is
enabled in the crane control EEPROMs). If the crane
function enable switch is inactive, all statuses will show
disabled.
Special Notes
Swing
- Whenever the swing brake switch is active, swing
function is disabled and the indicator reflects this status.
Main and Aux Hoist
- If the hoist high speed switch is active
and the hoist is active, high speed indication will be
displayed as two right-facing arrows in the lower right corner
of the indicator. Whenever the hoist is inactive or disabled,
the high speed indication will not be visible.
Reference Only