www.mc-techgroup.com
MP48-R | 1.00.00
29
CLEANING THE PUMP
Note
When cleaning, make sure that no liquids enter the inside of the housing.
Flushing the pump
When transferring aggressive media, flush the pump under atmospheric conditions some minutes with
air (or, if necessary, for safety reasons, with an inert gas) prior to switch-off to increase the service life
of the diaphragm.
Cleaning the pump
Only use solvents for cleaning if the head materials cannot be attacked (check the resistance of
the material!).
If compressed air is available, blow out the components.
REPLACING DIAPHRAGM AND VALVE PLATES
1
Housing
2
Intermediate plate
3
Head platel
4
Pressure plate
5
Screws
6
Diaphragm
7
Center screw
8
Shim
9
Valve plate/sealing
10
O-ring
11
Throttle valve
12
Guide pin
Figure 11 Exploded view pump head MP48-R