MP48-R | 1.00.00
21
Note
Incorrect mains voltage can destroy the device.
When connecting, ensure that the mains voltage is correct according to
the information on the type plate! The supply voltage may deviate by
max. +6 % or -10 % from the specifications on the type plate.
Note
When installing power installations with nominal voltages up to 1000 V,
the requirements of VDE 0100 and its relevant standards and regula-
tions must be observed!
Install a device for disconnecting the pump motor from the electrical
mains in the electrical installation (according to EN 60204-1).
Observe the relevant standards, directives, regulations and technical standards when making
the electrical connection.
The supply circuit of the pump type
MP48-R
(230 V) must be equipped with a motor protection
switch 0.63 - 1 A corresponding to the rated current; (overcurrent protection).
The supply circuit of the pump type
MP48-R
(115 V) must be equipped with a motor circuit
breaker 1 - 1.6 A corresponding to the rated current (overcurrent protection).
Protect the pump motors according to EN 60204-1 (overcurrent protection, overload protection).
The max. current consumption of the pump is listed on the pump type plate.
It is recommended to install an additional EMERGENCY STOP device.
Install the pumps in such a way that contact with the live parts (electrical connection) is impos-
sible.
12.3.1 ATTACHING CONNECTION CABLES
Fasten the connection cables in such a way that:
the cables do not come into contact with moving or hot parts.
the cables do not chafe or become damaged on sharp corners or edges.
no tensile or compressive forces are applied to the connection point of the cables (strain relief).
The pumps are protected against overload by a thermoswitch (capacitor motor) as standard.
12.3.2 CONNECTING THE PUMP
1. Compare the supply voltage data with the data on the motor type plate. Refer to the pump type
plate for the maximum current consumption of the pump.