www.mc-techgroup.com
MP48-R | 1.00.00
15
The elastic diaphragm (Figure 4/4) is moved up and down by the eccentric (Figure 4/5) and the connec-
tion rod (Figure 4/6). In the downward stroke it aspirates the gas to be transferred via the inlet valve
(Figure 4/2). In the upward stroke, the diaphragm presses the medium out of the pump head via the
outlet valve (Figure 4/1). The transfer chamber (Figure 4/3) is hermetically separated from the pump
drive (Figure 4/7) by the diaphragm.
11
TRANSPORT, RECEIPT OF GOODS AND STORAGE
Caution
Personal injury and/or damage to property because of false or improper
transportation of the pump.
Due to false or improper transportation the pump can fall down, become
damaged and injure people.
If necessary, use suitable aids (eyebolt, harness, lifting device, etc.).
Wear proper personal protective equipment (e.g., safety gloves, safety
shoes).
Caution
Danger of injury due to sharp edges on the package
When handling or opening the package there is the possibility of injury
by cutting at sharp edges.
Wear proper personal protective equipment (e.g., safety gloves,
safety shoes).
Check the goods for possible transport damage. Document any transport damage that has oc-
curred in writing and with pictures. Inform your transport insurer immediately of any damages.
Transport the pump in its original packaging to the installation site.
Carefully remove the diaphragm pump and any special accessories from the shipping packaging
immediately after arrival and check the scope of delivery according to the delivery note.
Keep the original packaging of the pump (e.g., for later storage).
Note
The equipment should be stored in a protected, frost-free room!