23
BA
TTERIA
BA
TT
ER
IA
+
-
N
12
V
NO
OK
NO
OK
NO
OK
Tester (
Ω
)
BATTERIA
BATTERIA
+
-
N
12 V
2
1
3
4
M
B
F. 12
F. 13
E L E C T R I C A L S T A R T I N G S Y S T E M
E L E C T R I C A L S T A R T I N G S Y S T E M
Clean terminals.
Top up with distilled water.
Recharge or replace battery.
•
•
•
3.
Starter motor
Connect a 12 V battery to starter motor:
Battery (+) pole
Terminal (+) of starter motor
(1)
.
Battery (-) pole
Terminal (-) of starter motor
(2).
•
•
•
Check operation of the starter motor.
•
To connect, use cables that are compatible with the power draw of the starter motor.
Replace starter motor.
4.
Starter relay
Disconnect starter relay.
Connect a 12 V battery to the starter relay:
Battery (+) pole
Terminal
(3)
.
Battery (-) pole
Terminal
(4)
.
•
•
•
•
Connect tester (
Ω
)
to terminals
(B)
and
(M)
of starter relay.
Check continuity.
•
•
B:
Battery cable
Starter relay.
M:
Starter relay cable
Starter motor.
Replace starter relay.
Summary of Contents for X3Motard