20
NO
OK
NO
OK
5
6
Tester (
Ω
)
OK
Tester (
Ω
)
1
2
Tester k
Ω
1
3
Tester
Ω
F. 6
F. 7
F. 8
I G N I T I O N S Y S T E M
I G N I T I O N S Y S T E M
5.
HV coil resistance
Disconnect orange cable.
Connect
Tester (
Ω
)
to HV coil.
Check resistance of coil’s primary winding: 0.9
Ω
± 10% at 20°C.
Terminal (+) of Tester
Terminal
(1)
.
Terminal (-) of Tester
Ground
(2)
.
•
•
•
•
•
Check resistance of coil’s secondary winding: 7.30 K
Ω
± 10% at 20°C
.
Terminal (+) of Tester
Terminal
(1)
.
Terminal (-) of Tester
Spark plug cable
(3)
.
•
•
•
Replace ignition coil.
6.
Key switch
Disconnect key switch from system.
Turn key “ON”.
•
•
Connect
Tester (
Ω
)
and check continuity of key switch as follows:
Terminal (+) of Tester
Orange
cable
(5)
.
Terminal (-) of Tester
Green cable
(6)
.
•
•
•
Replace key switch.