40
Tester (
Ω
)
1
3
2
NO
OK
F. 39
S I G N A L L I N G S Y S T E M
S I G N A L L I N G S Y S T E M
TURN INDICATORS AND RELATIVE INDICATOR LIGHT DO NOT WORK
Check:
1. Turn indicator switch
2. Voltage level of
fl
ashlight
3. Continuity of brown cable
1.
Turn indicator switch
Disconnect nine-way cable of left hand switch.
Flick switch to activate right hand turn indicators.
Connect
Tester (
Ω
)
as follows:
Terminal (+) of Tester
Brown
cable
(1)
.
Terminal (-) of Tester
Green cable
(2).
Check continuity.
Flick switch to activate left hand turn indicators.
Connect
Tester (
Ω
)
as follows:
Terminal (+) of Tester
Brown cable
(1)
.
Terminal (-) of Tester
Purple cable
(3).
Check continuity.
•
•
•
•
•
•
•
•
•
•
•
Turn switch is faulty.
Replace left hand switch
•
•
Summary of Contents for X3Motard
Page 1: ......